Back to Search Start Over

Autosomal SNP typing of forensic samples with the GenPlex™ HID System: results of a collaborative study.

Authors :
Tomas C
Axler-DiPerte G
Budimlija ZM
Børsting C
Coble MD
Decker AE
Eisenberg A
Fang R
Fondevila M
Fredslund SF
Gonzalez S
Hansen AJ
Hoff-Olsen P
Haas C
Kohler P
Kriegel AK
Lindblom B
Manohar F
Maroñas O
Mogensen HS
Neureuther K
Nilsson H
Scheible MK
Schneider PM
Sonntag ML
Stangegaard M
Syndercombe-Court D
Thacker CR
Vallone PM
Westen AA
Morling N
Source :
Forensic science international. Genetics [Forensic Sci Int Genet] 2011 Nov; Vol. 5 (5), pp. 369-75. Date of Electronic Publication: 2010 Jul 22.
Publication Year :
2011

Abstract

The GenPlex™ HID System (Applied Biosystems - AB) offers typing of 48 of the 52 SNPforID SNPs and amelogenin. Previous studies have shown a high reproducibility of the GenPlex™ HID System using 250-500pg DNA of good quality. An international exercise was performed by 14 laboratories (9 in Europe and 5 in the US) in order to test the robustness and reliability of the GenPlex™ HID System on forensic samples. Three samples with partly degraded DNA and 10 samples with low amounts of DNA were analyzed in duplicates using various amounts of DNA. In order to compare the performance of the GenPlex™ HID System with the most commonly used STR kits, 500pg of partly degraded DNA from three samples was typed by the laboratories using one or more STR kits. The median SNP typing success rate was 92.3% with 500pg of partly degraded DNA. Three of the fourteen laboratories counted for more than two thirds of the locus dropouts. The median percentage of discrepant results was 0.2% with 500pg degraded DNA. An increasing percentage of locus dropouts and discrepant results were observed when lower amounts of DNA were used. Different success rates were observed for the various SNPs. The rs763869 SNP was the least successful. With the exception of the MiniFiler™ kit (AB), GenPlex™ HID performed better than five other tested STR kits. When partly degraded DNA was analyzed, GenPlex™ HID showed a very low mean mach probability, while all STR kits except MiniFiler™ had very limited discriminatory power.<br /> (Copyright © 2010 Elsevier Ireland Ltd. All rights reserved.)

Details

Language :
English
ISSN :
1878-0326
Volume :
5
Issue :
5
Database :
MEDLINE
Journal :
Forensic science international. Genetics
Publication Type :
Academic Journal
Accession number :
20650697
Full Text :
https://doi.org/10.1016/j.fsigen.2010.06.007