Back to Search Start Over

First clinical application of an actively reversible direct factor IXa inhibitor as an anticoagulation strategy in patients undergoing percutaneous coronary intervention.

Authors :
Cohen MG
Purdy DA
Rossi JS
Grinfeld LR
Myles SK
Aberle LH
Greenbaum AB
Fry E
Chan MY
Tonkens RM
Zelenkofske S
Alexander JH
Harrington RA
Rusconi CP
Becker RC
Source :
Circulation [Circulation] 2010 Aug 10; Vol. 122 (6), pp. 614-22. Date of Electronic Publication: 2010 Jul 26.
Publication Year :
2010

Abstract

Background: The ideal anticoagulant should prevent ischemic complications without increasing the risk of bleeding. Controlled anticoagulation is possible with the REG1 system, an RNA aptamer pair comprising the direct factor IXa inhibitor RB006 and its active control agent RB007.<br />Methods and Results: This phase 2a study included a roll-in group (n=2) treated with REG1 plus glycoprotein IIb/IIIa inhibitors followed by 2 groups randomized 5:1 to REG1 or unfractionated heparin. In group 1 (n=12), RB006 was partially reversed with RB007 after percutaneous coronary intervention and fully reversed 4 hours later. In group 2 (n=12), RB006 was fully reversed with RB007 immediately after percutaneous coronary intervention. Femoral sheaths were removed after complete reversal. Patients were pretreated with aspirin and clopidogrel. End points included major bleeding within 48 hours; composite of death, myocardial infarction, or urgent target vessel revascularization within 14 days; and pharmacodynamic measures. All cases were successful, with final Thrombolysis in Myocardial Infarction grade 3 flow and no angiographic thrombotic complications. There were 2 ischemic end points in the REG1 group and 1 in the unfractionated heparin group, with 1 major bleed in the unfractionated heparin group. Median activated clotting time values rose from 151 to 236 seconds after RB006. Administration of the partial RB007 dose reversed anticoagulation to an intermediate activated clotting time value of 186 seconds. Complete reversal with RB007 returned the median activated clotting time value to 144 seconds. Both reversal strategies enabled scheduled femoral sheath removal.<br />Conclusions: This study demonstrates the clinical translation of a novel platform of anticoagulation targeting factor IXa and its active reversal to percutaneous coronary intervention and provides the basis for further investigation.<br />Clinical Trial Registration: URL: http://www.clinicaltrials.gov. Unique identifier: NCT00715455.

Details

Language :
English
ISSN :
1524-4539
Volume :
122
Issue :
6
Database :
MEDLINE
Journal :
Circulation
Publication Type :
Academic Journal
Accession number :
20660806
Full Text :
https://doi.org/10.1161/CIRCULATIONAHA.109.927756