Back to Search Start Over

Radiostrontium and radium analysis in low-level environmental samples following a multi-stage semi-automated chromatographic sequential separation.

Authors :
St-Amant N
Whyte JC
Rousseau ME
Lariviere D
Ungar RK
Johnson S
Source :
Applied radiation and isotopes : including data, instrumentation and methods for use in agriculture, industry and medicine [Appl Radiat Isot] 2011 Jan; Vol. 69 (1), pp. 8-17. Date of Electronic Publication: 2010 Aug 25.
Publication Year :
2011

Abstract

Strontium isotopes, (89)Sr and (90)Sr, and (226)Ra being radiotoxic when ingested, are routinely monitored in milk and drinking water samples collected from different regions in Canada. In order to monitor environmental levels of activity, a novel semi-automated sensitive method has been developed at the Radiation Protection Bureau of Health Canada (Ottawa, Canada). This method allows the separation and quantification of both (89)Sr and (90)Sr and has also been adapted to quantify (226)Ra during the same sample preparation procedure. The method uses a 2-stage purification process during which matrix constituents, such as magnesium and calcium that are rich in milk, are removed as well as the main beta-interferences (e.g., (40)K, (87)Rb, (134)Cs, (137)Cs, and (140)Ba). The first purification step uses strong cation exchange (SCX) chromatography with commercially available resins. In a second step, fractions containing the radiostrontium analytes are further purified using high-performance ion chromatography (HPIC). While (89)Sr is quantified by Cerenkov counting immediately after the second purification stage, the same vial is counted again after a latent period of 10-14 days to quantify the (90)Sr activity based on (90)Y ingrowth. Similarly, the activity of (226)Ra, which is separated by SCX only, is determined via the emanation of (222)Rn in a 2-phase aqueous/cocktail system using liquid scintillation counting. The minimum detectable concentration (MDC) for (89)Sr and (90)Sr for a 200 min count time at 95% confidence interval is 0.03 and 0.02 Bq/L, respectively. The MDC for (226)Ra for a 100 min count time is 0.002 Bq/L. Semi-annual intercomparison samples from the USA Department of Energy Mixed Analyte Performance Evaluation Program (MAPEP) were used to validate the method for (89)Sr and (90)Sr. Spiked water samples prepared in-house and from International Atomic Energy Agency (IAEA) were used to validate the (226)Ra assay.<br /> (Crown Copyright © 2010. Published by Elsevier Ltd. All rights reserved.)

Details

Language :
English
ISSN :
1872-9800
Volume :
69
Issue :
1
Database :
MEDLINE
Journal :
Applied radiation and isotopes : including data, instrumentation and methods for use in agriculture, industry and medicine
Publication Type :
Academic Journal
Accession number :
20846869
Full Text :
https://doi.org/10.1016/j.apradiso.2010.08.001