Back to Search Start Over

Wall reflection issues for optical diagnostics in fusion devices.

Authors :
Lotte P
Aumeunier MH
Devynck P
Fenzi C
Martin V
Travère JM
Source :
The Review of scientific instruments [Rev Sci Instrum] 2010 Oct; Vol. 81 (10), pp. 10E120.
Publication Year :
2010

Abstract

The problem of light reflection has been raised as a high priority issue for optical diagnostics in next step fusion devices where metallic wall environment will generate significant perturbations in the diagnostics measurements. Tore Supra is a large size tokamak equipped with water-cooled stainless-steel panels used to sustain the plasma long shot radiations. These panels are highly reflective and affect significantly optical systems. In particular, we show that the infrared imaging diagnostic, which surveys the plasma facing component surface temperature for safety purposes, can give incorrect information due to reflected light coming from the bottom limiter. In the visible range, motional Stark effect and Zeff measurements experience important drifts during the plasma heating phases due to parasitic light coming from the limiter, but also from the plasma itself when the viewing lines are facing the reflecting walls. In the next step fusion devices such as ITER, the possibility to use optical measurements needs to be accessed by a modeling of the diagnostic light in its machine environment and the development of new techniques of online correction.

Details

Language :
English
ISSN :
1089-7623
Volume :
81
Issue :
10
Database :
MEDLINE
Journal :
The Review of scientific instruments
Publication Type :
Academic Journal
Accession number :
21033985
Full Text :
https://doi.org/10.1063/1.3474653