Back to Search Start Over

Outcome of cataract surgery in Nigeria: visual acuity, autorefraction, and optimal intraocular lens powers--results from the Nigeria national survey.

Authors :
Imam AU
Gilbert CE
Sivasubramaniam S
Murthy GV
Maini R
Rabiu MM
Source :
Ophthalmology [Ophthalmology] 2011 Apr; Vol. 118 (4), pp. 719-24. Date of Electronic Publication: 2010 Nov 04.
Publication Year :
2011

Abstract

Objective: To describe presenting and corrected visual acuities after cataract surgery in a nationally representative sample of adults. Another objective was to describe refractive errors in operated eyes and to determine the optimal range of intraocular lens (IOL) powers for this population.<br />Design: Cross-sectional, population-based survey.<br />Participants: Adults aged 40 years and more were selected using multistage stratified sampling and proportional to size procedures. A sample size of 15027 was calculated, and clusters were selected from all states.<br />Methods: Individuals who had undergone cataract surgery were identified from interview and examination. All had their presenting visual acuity (VA) measured using a reduced logarithm of the minimum angle of resolution chart and underwent autorefraction. Corrected VAs were assessed using the autorefraction results in a trial set. An ophthalmologist conducted all examinations, including slit-lamp and dilated fundus examination. Causes of visual loss were determined for all eyes with a presenting VA <6/12 using the World Health Organization recommendations. Biometry data were derived from 20449 phakic eyes using the SRK-T formula after excluding those with poor VA or corneal opacities.<br />Main Outcome Measures: Presenting and corrected visual acuities in pseudo/aphakic individuals and autorefraction findings; biometry profile of Nigerian adults.<br />Results: Data from 288 eyes of 217 participants were analyzed. Only 39.5% of eyes had undergone IOL implantation at surgery. Only 29.9% of eyes had a good outcome (i.e., ≥6/18) at presentation, increasing to 55.9% with correction. Use of an IOL was the only factor associated with a good outcome at presentation (odds ratio 9.0; 95% confidence interval, 4.3-18.9; P=0.001). Eyes undergoing cataract surgery had a higher prevalence and degree of astigmatism than phakic eyes. Biometry data reveal that posterior chamber IOL powers of 20, 21, and 22 diopters (D) (A constant 118.0) will give a postoperative refraction range of -2.0 D to emmetropia in 71.4% of eyes, which increases to 82.6% if 19 D is also included.<br />Conclusions: Postoperative astigmatism needs to be reduced through better surgical techniques and training, and use of biometry should be standard of care.<br /> (Copyright © 2011 American Academy of Ophthalmology. Published by Elsevier Inc. All rights reserved.)

Details

Language :
English
ISSN :
1549-4713
Volume :
118
Issue :
4
Database :
MEDLINE
Journal :
Ophthalmology
Publication Type :
Academic Journal
Accession number :
21055820
Full Text :
https://doi.org/10.1016/j.ophtha.2010.08.025