Back to Search
Start Over
An embolic deflection device for aortic valve interventions.
- Source :
-
JACC. Cardiovascular interventions [JACC Cardiovasc Interv] 2010 Nov; Vol. 3 (11), pp. 1133-8. - Publication Year :
- 2010
-
Abstract
- Objectives: We describe initial human experience with a novel cerebral embolic protection device.<br />Background: Cerebral emboli are the major cause of procedural stroke during percutaneous aortic valve interventions.<br />Methods: With right radial artery access, the embolic protection device is advanced into the aortic arch. Once deployed a porous membrane shields the brachiocephalic trunk and the left carotid artery deflecting emboli away from the cerebral circulation. Embolic material is not contained or removed by the device. The device was used in 4 patients (mean age 90 years) with severe aortic stenosis undergoing aortic balloon valvuloplasty (n = 1) or transcatheter aortic valve implantation (n = 3).<br />Results: Correct placement of the embolic protection device was achieved without difficulty in all patients. Continuous brachiocephalic and aortic pressure monitoring documented equal pressures without evidence of obstruction to cerebral perfusion. Additional procedural time due to the use of the device was 13 min (interquartile range: 12 to 16 min). There were no procedural complications. Pre-discharge cerebral magnetic resonance imaging found no new defects in any of 3 patients undergoing transcatheter aortic valve implantation and a new 5-mm acute cortical infarct in 1 asymptomatic patient after balloon valvuloplasty alone. No patient developed new neurological symptoms or clinical findings of stroke.<br />Conclusions: Embolic protection during transcatheter aortic valve intervention seems feasible and might have the potential to reduce the risk of cerebral embolism and stroke.<br /> (Copyright © 2010 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.)
- Subjects :
- Aged, 80 and over
Aortic Valve Stenosis physiopathology
Blood Pressure
British Columbia
Cardiac Catheterization adverse effects
Cardiac Catheterization methods
Catheterization
Feasibility Studies
Female
Heart Valve Prosthesis Implantation adverse effects
Heart Valve Prosthesis Implantation methods
Humans
Intracranial Embolism diagnosis
Intracranial Embolism etiology
Magnetic Resonance Imaging
Male
Prosthesis Design
Radial Artery
Radiography, Interventional
Stroke etiology
Stroke prevention & control
Time Factors
Treatment Outcome
Aortic Valve Stenosis therapy
Cardiac Catheterization instrumentation
Embolic Protection Devices
Heart Valve Prosthesis Implantation instrumentation
Intracranial Embolism prevention & control
Subjects
Details
- Language :
- English
- ISSN :
- 1876-7605
- Volume :
- 3
- Issue :
- 11
- Database :
- MEDLINE
- Journal :
- JACC. Cardiovascular interventions
- Publication Type :
- Academic Journal
- Accession number :
- 21087748
- Full Text :
- https://doi.org/10.1016/j.jcin.2010.05.022