Back to Search Start Over

Graphic-output temperature data loggers for monitoring vaccine refrigeration: implications for pertussis.

Authors :
McColloster P
Vallbona C
Source :
American journal of public health [Am J Public Health] 2011 Jan; Vol. 101 (1), pp. 46-7. Date of Electronic Publication: 2010 Nov 18.
Publication Year :
2011

Abstract

We conducted the first US study using graphic-output temperature data loggers in quantifying cold chain failure. Fifty-four vaccine refrigerators of a county outpatient health system were studied. Forty-eight percent maintained temperatures of 2°C to 8°C and 24% had protracted periods of temperatures less than 0°C. The correlation between the percentage of refrigerators with freezing temperatures and the pertussis rate for each health region was r = 0.76. The findings suggest that improper vaccine storage may have contributed to recent increases in pertussis rates.

Details

Language :
English
ISSN :
1541-0048
Volume :
101
Issue :
1
Database :
MEDLINE
Journal :
American journal of public health
Publication Type :
Academic Journal
Accession number :
21088272
Full Text :
https://doi.org/10.2105/AJPH.2009.179853