Back to Search
Start Over
Is a silastic radial head still a reasonable option?
- Source :
-
Clinical orthopaedics and related research [Clin Orthop Relat Res] 2011 Apr; Vol. 469 (4), pp. 1061-70. - Publication Year :
- 2011
-
Abstract
- Background: The importance of the radial head to elbow function and stability is increasingly apparent. Although preservation of the native radial head is preferred, severely comminuted fractures may necessitate resection or arthroplasty. Silastic radial head arthroplasty has been condemned on the basis of several sporadic reports of silicone synovitis. However, problems of "overstuffing," cartilage wear, and motion loss are becoming apparent with metal prostheses, indicating this also is not an ideal solution. Thus, the choices remain controversial.<br />Questions/purposes: We asked whether intact or reconstructed primary elbow stabilizers permit use of silastic radial head implants without fragmentation, failure, and silicone synovitis.<br />Methods: We retrospectively reviewed 23 patients with unreconstructable radial head fractures who were treated with silastic radial head arthroplasty and concomitant repair and/or reconstruction of the medial ulnar collateral ligament and/or lateral ulnar collateral ligament. Analysis included range of motion, pain, stability, and radiographic assessments; Disabilities of the Arm, Shoulder, and Hand (DASH) questionnaire; and Mayo Elbow Performance Score (MEPS). The minimum followup was 16 months (average, 69.6 months; range, 16-165 months).<br />Results: At last followup, the mean elbow flexion was 145°, extension 11°, supination 80°, and pronation 83°. The mean MEPS score was 88.9. The mean DASH score was 11.8. There were eight reoperations, none resulting from failure of the radial head implants.<br />Conclusions: These results demonstrate silastic radial heads can be used with low complication rates and without evidence of synovitis when concomitant elbow ligament repair or reconstruction is performed.<br />Level of Evidence: Level IV, therapeutic study. See Guidelines for Authors for a complete description of levels of evidence.
- Subjects :
- Adult
Aged
Arthroplasty, Replacement adverse effects
Disability Evaluation
Elbow Joint diagnostic imaging
Elbow Joint physiopathology
Female
Fractures, Comminuted diagnostic imaging
Fractures, Comminuted physiopathology
Humans
Joint Instability etiology
Joint Instability prevention & control
Male
Middle Aged
New York City
Pain Measurement
Pain, Postoperative etiology
Pain, Postoperative prevention & control
Prosthesis Design
Prosthesis Failure
Radiography
Radius Fractures diagnostic imaging
Radius Fractures physiopathology
Range of Motion, Articular
Recovery of Function
Retrospective Studies
Synovitis etiology
Synovitis prevention & control
Time Factors
Treatment Outcome
Young Adult
Arthroplasty, Replacement instrumentation
Dimethylpolysiloxanes
Elbow Joint surgery
Fractures, Comminuted surgery
Joint Prosthesis
Radius Fractures surgery
Subjects
Details
- Language :
- English
- ISSN :
- 1528-1132
- Volume :
- 469
- Issue :
- 4
- Database :
- MEDLINE
- Journal :
- Clinical orthopaedics and related research
- Publication Type :
- Academic Journal
- Accession number :
- 21089001
- Full Text :
- https://doi.org/10.1007/s11999-010-1672-2