Coherence in depth electrodes during induction of deep anesthesia.

Authors :
Silfverhuth MJ
Kortelainen J
Sonkajärvi E
Suominen K
Alahuhta S
Jäntti V
Seppänen T
Source :
Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual International Conference [Annu Int Conf IEEE Eng Med Biol Soc] 2010; Vol. 2010, pp. 5963-6.
Publication Year :
2010

Abstract

Our aim was to explore time-varying coherence values versus spacing and referencing of electrode contacts in thalamic level from human encephalographic (EEG) data. Data has been acquired during induction of propofol anesthesia until burst-suppression level in scalp EEG. Results are shown from coherence analysis applied to EEG signals from selected depth electrode contacts pair-wise of three subjects. Alpha coherence is the most prominent behavior in all channel pairs. It is persistent throughout the time period followed and in coherence calculated between bipolar derivations in depth electrodes.

Details

Language :
English
ISSN :
2375-7477
Volume :
2010
Database :
MEDLINE
Journal :
Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual International Conference
Publication Type :
Academic Journal
Accession number :
21096949
Full Text :
https://doi.org/10.1109/IEMBS.2010.5627573