Back to Search Start Over

Diagnostic performance of two types of low radiation exposure protocol for prospective ECG-triggering multidetector computed tomography angiography in assessment of coronary artery bypass graft.

Authors :
Andreini D
Pontone G
Mushtaq S
Annoni A
Formenti A
Bertella E
Parolari A
Agostoni P
Bartorelli A
Ballerini G
Fiorentini C
Pepi M
Source :
International journal of cardiology [Int J Cardiol] 2012 May 17; Vol. 157 (1), pp. 63-9. Date of Electronic Publication: 2010 Dec 28.
Publication Year :
2012

Abstract

Background: Multidetector computed tomography (MDCT) is useful in evaluation of coronary artery bypass graft (CABG). However, radiation exposure is a reason for concern. We compared diagnostic performance and effective dose of a new dedicated post-processing reconstruction algorithm with BMI-adapted scanning protocol (MDCT-XTe) vs. standard prospective ECG-triggering protocol (MDCT-XT) and retrospective ECG-triggering (MDCT-Helical), compared to invasive coronary angiography (ICA), in the assessment of grafts and nongrafted or distal runoff coronary arteries.<br />Methods: One hundred and nineteen patients with 277 grafts were randomized to Group 1 based on BMI-adapted scanning protocol with prospective ECG-triggering (40 patients), Group 2 with prospective ECG-triggering (39 patients) and Group 3 (40 patients) with retrospective ECG-triggering. Data were acquired using 64-slice MDCT.<br />Results: MDCT correctly assessed the patency of all CABG in 3 groups. After comparison with ICA, MDCT was able to correctly detect the occlusion or stenosis of CABG in all groups, with the exception of one case of Group 3. In Group 3 sensitivity, specificity, positive predictive value, negative predictive value and accuracy of CABG evaluation were 100%, 98.4%, 96.7%, 100% and 98.9%, respectively. In Groups 1 and 2 the diagnostic accuracy of CABG evaluation was 100%. Effective radiation dose was 3.5±1.4mSv in Group 1 vs. 7.4±2.6mSv in Group 2 vs. 27.8±9.4mSv in Group 3.<br />Conclusions: Our results indicated that MDCT-XTe and MDCT-XT have a diagnostic performance in the evaluation of CABG similar to MDCT-Helical, with a significant reduction of radiation exposure, specially for MDCT-XTe.<br /> (Copyright © 2010 Elsevier Ireland Ltd. All rights reserved.)

Details

Language :
English
ISSN :
1874-1754
Volume :
157
Issue :
1
Database :
MEDLINE
Journal :
International journal of cardiology
Publication Type :
Academic Journal
Accession number :
21193234
Full Text :
https://doi.org/10.1016/j.ijcard.2010.11.015