Measurement of aortic valve annulus using different cardiac imaging techniques in transcatheter aortic valve implantation: agreement with finally implanted prosthesis size.
- Source :
-
Echocardiography (Mount Kisco, N.Y.) [Echocardiography] 2011 Apr; Vol. 28 (4), pp. 388-96. - Publication Year :
- 2011
-
Abstract
- Aims: To compare the measurements of the aortic annulus obtained with various imaging techniques in patients with severe aortic stenosis scheduled for transcatheter aortic valve implantation, and to determine the grade of agreement between the predicted size of the prosthesis for each technique, and the size of the finally implanted valve.<br />Methods and Results: The aortic annulus was measured in 40 patients treated by transcatheter aortic valve implantation (CoreValve aortic valve) with transthoracic (TTE) and transesophageal echocardiography (TEE), 64-slice tomography, and angiography. A large valve was implanted when annulus was >23 mm and a small one if it was ≤23 mm. If the size of the prosthesis predicted by several techniques was not the same in one case, we selected the size in which more techniques presented agreement. Forty aortic valves, 26 small and 14 large, were implanted percutaneously. The best correlation was obtained with TTE and TEE (r = 0.93, P < 0.001). The correlation of TTE and TEE with angiography also was good (r = 0.58, P < 0.001 and r = 0.53, P < 0.001, respectively). Correlations between these techniques and computed tomography were poor (P = NS for all comparisons). The best agreement between estimated aortic annulus and implanted valve size was obtained with transtoracic and TEE (κ= 0.88 and 0.76).<br />Conclusions: The aortic annulus measurements obtained by TTE, TEE, and angiography correlated well, while tomography correlated poorly with other techniques. The imaging techniques that showed the best agreement between estimated aortic annulus size and implanted aortic valve size were TTE and TEE.<br /> (© 2011, Wiley Periodicals, Inc.)
- Subjects :
- Aged
Aged, 80 and over
Coronary Angiography methods
Echocardiography methods
Female
Humans
Male
Predictive Value of Tests
Prosthesis Design
Tomography, X-Ray Computed methods
Treatment Outcome
Aortic Valve diagnostic imaging
Aortic Valve surgery
Aortic Valve Stenosis diagnostic imaging
Aortic Valve Stenosis surgery
Heart Valve Prosthesis
Heart Valve Prosthesis Implantation methods
Subjects
Details
- Language :
- English
- ISSN :
- 1540-8175
- Volume :
- 28
- Issue :
- 4
- Database :
- MEDLINE
- Journal :
- Echocardiography (Mount Kisco, N.Y.)
- Publication Type :
- Academic Journal
- Accession number :
- 21504463
- Full Text :
- https://doi.org/10.1111/j.1540-8175.2010.01353.x