Back to Search
Start Over
Incidence of asymptomatic intracranial embolic events after pulmonary vein isolation: comparison of different atrial fibrillation ablation technologies in a multicenter study.
- Source :
-
Journal of the American College of Cardiology [J Am Coll Cardiol] 2011 Aug 09; Vol. 58 (7), pp. 681-8. Date of Electronic Publication: 2011 Jun 12. - Publication Year :
- 2011
-
Abstract
- Objectives: We compared the safety of different devices by screening for subclinical intracranial embolic events after pulmonary vein isolation with either conventional irrigated radiofrequency (RF) or cryoballoon or multielectrode phased RF pulmonary vein ablation catheter (PVAC).<br />Background: New devices specifically designed to facilitate pulmonary vein isolation procedures have recently been introduced.<br />Methods: This prospective, observational, multicenter study included patients with symptomatic atrial fibrillation referred for pulmonary vein isolation. Ablation was performed using 1 of the 3 catheters. Strict periprocedural anticoagulation, with intravenous heparin during ablation to achieve an activated clotting time >300 s, was ensured in all patients. Cerebral magnetic resonance imaging was performed before and after ablation.<br />Results: Seventy-four patients were included in the study: 27 in the irrigated RF group, 23 in the cryoballoon group, and 24 in the PVAC group. Total procedure times were 198 ± 50 min, 174 ± 35 min, and 124 ± 32 min, respectively (p < 0.001 for PVAC vs. irrigated RF and cryoballoon). Findings on neurological examination were normal in all patients before and after ablation. Post-procedure magnetic resonance imaging detected a single new embolic lesion in 2 of 27 patients in the irrigated RF group (7.4%) and in 1 of 23 in the cryoballoon group (4.3%). However, in the PVAC group 9 of 24 patients (37.5%) demonstrated 2.7 ± 1.3 new lesions each (p = 0.003 for the presence of new embolic events among the 3 groups).<br />Conclusions: The PVAC is associated with a significantly higher incidence of subclinical intracranial embolic events. Further study of the causes and significance of these emboli is required to determine the safety of the PVAC.<br /> (Copyright © 2011 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.)
- Subjects :
- Anticoagulants administration & dosage
Catheter Ablation instrumentation
Catheter Ablation methods
Cryosurgery adverse effects
Diffusion Magnetic Resonance Imaging
Female
Humans
Intracranial Embolism diagnosis
Intracranial Embolism pathology
Male
Middle Aged
Neurologic Examination
Therapeutic Irrigation
Atrial Fibrillation surgery
Catheter Ablation adverse effects
Intracranial Embolism etiology
Pulmonary Veins surgery
Subjects
Details
- Language :
- English
- ISSN :
- 1558-3597
- Volume :
- 58
- Issue :
- 7
- Database :
- MEDLINE
- Journal :
- Journal of the American College of Cardiology
- Publication Type :
- Academic Journal
- Accession number :
- 21664090
- Full Text :
- https://doi.org/10.1016/j.jacc.2011.04.010