Back to Search Start Over

Caveats and limitations of plate reader-based high-throughput kinetic measurements of intracellular calcium levels.

Authors :
Heusinkveld HJ
Westerink RH
Source :
Toxicology and applied pharmacology [Toxicol Appl Pharmacol] 2011 Aug 15; Vol. 255 (1), pp. 1-8. Date of Electronic Publication: 2011 Jun 12.
Publication Year :
2011

Abstract

Calcium plays a crucial role in virtually all cellular processes, including neurotransmission. The intracellular Ca(2+) concentration ([Ca(2+)](i)) is therefore an important readout in neurotoxicological and neuropharmacological studies. Consequently, there is an increasing demand for high-throughput measurements of [Ca(2+)](i), e.g. using multi-well microplate readers, in hazard characterization, human risk assessment and drug development. However, changes in [Ca(2+)](i) are highly dynamic, thereby creating challenges for high-throughput measurements. Nonetheless, several protocols are now available for real-time kinetic measurement of [Ca(2+)](i) in plate reader systems, though the results of such plate reader-based measurements have been questioned. In view of the increasing use of plate reader systems for measurements of [Ca(2+)](i) a careful evaluation of current technologies is warranted. We therefore performed an extensive set of experiments, using two cell lines (PC12 and B35) and two fluorescent calcium-sensitive dyes (Fluo-4 and Fura-2), for comparison of a linear plate reader system with single cell fluorescence microscopy. Our data demonstrate that the use of plate reader systems for high-throughput real-time kinetic measurements of [Ca(2+)](i) is associated with many pitfalls and limitations, including erroneous sustained increases in fluorescence, limited sensitivity and lack of single cell resolution. Additionally, our data demonstrate that probenecid, which is often used to prevent dye leakage, effectively inhibits the depolarization-evoked increase in [Ca(2+)](i). Overall, the data indicate that the use of current plate reader-based strategies for high-throughput real-time kinetic measurements of [Ca(2+)](i) is associated with caveats and limitations that require further investigation.<br /> (Copyright © 2011 Elsevier Inc. All rights reserved.)

Details

Language :
English
ISSN :
1096-0333
Volume :
255
Issue :
1
Database :
MEDLINE
Journal :
Toxicology and applied pharmacology
Publication Type :
Academic Journal
Accession number :
21684299
Full Text :
https://doi.org/10.1016/j.taap.2011.05.020