Back to Search
Start Over
Dual arc volumetric-modulated arc radiotherapy (VMAT) of nasopharyngeal carcinomas: a simultaneous integrated boost treatment plan comparison with intensity-modulated radiotherapies and single arc VMAT.
- Source :
-
Clinical oncology (Royal College of Radiologists (Great Britain)) [Clin Oncol (R Coll Radiol)] 2012 Apr; Vol. 24 (3), pp. 196-207. Date of Electronic Publication: 2011 Jul 12. - Publication Year :
- 2012
-
Abstract
- Aims: To compare the performance of volumetric-modulated arc radiotherapy (VMAT) by dual arc with fixed beam intensity-modulated radiotherapies (IMRTs) and single arc VMAT on nasopharyngeal carcinomas (NPC).<br />Materials and Methods: Twenty NPC cases were re-planned using the planning system of the Pinnacle(3®)SmartArc (SA) module to compare the performance of the following four techniques: seven-field (7F) and 18-field (18F) fixed beam IMRT, and single (SA(1)) and dual arc VMAT (SA(2)). The plan was delivered on an Elekta Synergy™ Linac equipped with an 80-leaf 1cm multileaf collimator. Three dose levels of planning target volumes (PTVs) with 70/59.4/54.0Gy in 33 fractions were prescribed and delivered as a simultaneous integrated boost. The conformity index and homogeneity index of the PTVs, the comprehensive quality index (CQI), the normal tissue complication probability for the organs at risk (OARs), and the planning time, delivery efficiency and accuracy were analysed.<br />Results: A significantly inferior conformity index at the three dose levels of PTV and homogeneity index of PTV(70) were observed in SA(1) compared with the other techniques. Comparable conformity index and homogeneity index of the PTV were observed among 7F/18F IMRT and SA(2). Based on the CQI of the 11 OARs, the most efficient dose reduction was observed in 18F IMRT followed in order by SA(2), 7F IMRT and SA(1). The planning time was on average 13.2/24.9/40.1/42.8min for 7F/18F IMRT/SA(1)/SA(2), respectively. With regards to the delivery efficiency compared with 7F IMRT, a 51 and 41% reduction in delivery time was achieved by SA(1) and SA(2), respectively. All techniques presented a high quality assurance pass rate (>98%) of the Γ(3mm,3%) criterion.<br />Conclusion: In NPC cases, SA(2) gave superior results in terms of PTV coverage and OAR sparing compared with SA(1) and approached the performance achieved by 18F IMRT, but without sacrificing the delivery efficiency.<br /> (Copyright © 2011 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.)
- Subjects :
- Adult
Carcinoma
Cohort Studies
Female
Follow-Up Studies
Humans
Male
Middle Aged
Nasopharyngeal Carcinoma
Prognosis
Radiotherapy Dosage
Nasopharyngeal Neoplasms radiotherapy
Organs at Risk radiation effects
Photons therapeutic use
Quality Assurance, Health Care
Radiotherapy Planning, Computer-Assisted
Radiotherapy, Intensity-Modulated
Subjects
Details
- Language :
- English
- ISSN :
- 1433-2981
- Volume :
- 24
- Issue :
- 3
- Database :
- MEDLINE
- Journal :
- Clinical oncology (Royal College of Radiologists (Great Britain))
- Publication Type :
- Academic Journal
- Accession number :
- 21752615
- Full Text :
- https://doi.org/10.1016/j.clon.2011.06.006