Back to Search
Start Over
Dual source multidetector CT-angiography before Transcatheter Aortic Valve Implantation (TAVI) using a high-pitch spiral acquisition mode.
- Source :
-
European radiology [Eur Radiol] 2012 Jan; Vol. 22 (1), pp. 51-8. Date of Electronic Publication: 2011 Aug 17. - Publication Year :
- 2012
-
Abstract
- Objectives: Transcatheter Aortic Valve Implantation (TAVI) is an alternative to surgical valve replacement in high risk patients. Angiography of the aortic root, aorta and iliac arteries is required to select suitable candidates, but contrast agents can be harmful due to impaired renal function. We evaluated ECG-triggered high-pitch spiral dual source Computed Tomography (CT) with minimized volume of contrast agent to assess aortic root anatomy and vascular access.<br />Methods: 42 patients (82 ± 6 years) scheduled for TAVI underwent dual source (DS) CT angiography (CTA) of the aorta using a prospectively ECG-triggered high-pitch spiral mode (pitch = 3.4) with 40 mL iodinated contrast agent. We analyzed aortic root/iliac dimensions, attenuation, contrast to noise ratio (CNR), image noise and radiation exposure.<br />Results: Aortic root/iliac dimensions and distance of coronary ostia from the annulus could be determined in all cases. Mean aortic and iliac artery attenuation was 320 ± 70 HU and 340 ± 77 HU. Aortic/iliac CNR was 21.7 ± 6.8 HU and 14.5 ± 5.4 HU using 100 kV (18.8 ± 4.1 HU and 8.7 ± 2.6 HU using 120 kV). Mean effective dose was 4.5 ± 1.2 mSv.<br />Conclusions: High-pitch spiral DSCTA can be used to assess the entire aorta and iliac arteries in TAVI candidates with a low volume of contrast agent while preserving diagnostic image quality.
- Subjects :
- Aged, 80 and over
Aortic Valve pathology
Aortic Valve surgery
Aortic Valve Stenosis pathology
Aortic Valve Stenosis physiopathology
Artifacts
Body Mass Index
Contrast Media adverse effects
Electrocardiography
Female
Humans
Iliac Artery pathology
Iliac Artery surgery
Male
Preoperative Period
Prospective Studies
Radiation Dosage
Reproducibility of Results
Aortic Valve diagnostic imaging
Aortic Valve Stenosis diagnostic imaging
Aortic Valve Stenosis surgery
Cardiac Catheterization methods
Contrast Media administration & dosage
Coronary Angiography methods
Heart Valve Prosthesis Implantation
Iliac Artery diagnostic imaging
Multidetector Computed Tomography
Subjects
Details
- Language :
- English
- ISSN :
- 1432-1084
- Volume :
- 22
- Issue :
- 1
- Database :
- MEDLINE
- Journal :
- European radiology
- Publication Type :
- Academic Journal
- Accession number :
- 21845463
- Full Text :
- https://doi.org/10.1007/s00330-011-2233-0