TauroH-23-((75)Se)selena-25-homocholic acid (SeHCAT) retention has been used for the diagnosis of bile acid malabsorption since the early 1980s. Bile acid malabsorption has been increasingly recognized as an important cause of severe chronic diarroea with subsequent increase in the number of referrals for the SeHCAT test. In this study, we review and discuss the standard techniques for the measurement of SeHCAT retention and describe a simple and modified technique using a noncollimated whole-body scanner, suitable for most modern dual-headed cameras.