Performance studies of four-dimensional cone beam computed tomography.

Authors :
Qi Z
Chen GH
Source :
Physics in medicine and biology [Phys Med Biol] 2011 Oct 21; Vol. 56 (20), pp. 6709-21. Date of Electronic Publication: 2011 Sep 30.
Publication Year :
2011

Abstract

Four-dimensional cone beam computed tomography (4DCBCT) has been proposed to characterize the breathing motion of tumors before radiotherapy treatment. However, when the acquired cone beam projection data are retrospectively gated into several respiratory phases, the available data to reconstruct each phase is under-sampled and thus causes streaking artifacts in the reconstructed images. To solve the under-sampling problem and improve image quality in 4DCBCT, various methods have been developed. This paper presents performance studies of three different 4DCBCT methods based on different reconstruction algorithms. The aims of this paper are to study (1) the relationship between the accuracy of the extracted motion trajectories and the data acquisition time of a 4DCBCT scan and (2) the relationship between the accuracy of the extracted motion trajectories and the number of phase bins used to sort projection data. These aims will be applied to three different 4DCBCT methods: conventional filtered backprojection reconstruction (FBP), FBP with McKinnon-Bates correction (MB) and prior image constrained compressed sensing (PICCS) reconstruction. A hybrid phantom consisting of realistic chest anatomy and a moving elliptical object with known 3D motion trajectories was constructed by superimposing the analytical projection data of the moving object to the simulated projection data from a chest CT volume dataset. CBCT scans with gantry rotation times from 1 to 4 min were simulated, and the generated projection data were sorted into 5, 10 and 20 phase bins before different methods were used to reconstruct 4D images. The motion trajectories of the moving object were extracted using a fast free-form deformable registration algorithm. The root mean square errors (RMSE) of the extracted motion trajectories were evaluated for all simulated cases to quantitatively study the performance. The results demonstrate (1) longer acquisition times result in more accurate motion delineation for each method; (2) ten or more phase bins are necessary in 4DCBCT to ensure sufficient temporal resolution in tumor motion and (3) to achieve the same performance as FBP-4DCBCT with a 4 min data acquisition time, MB-4DCBCT and PICCS-4DCBCT need about 2- and 1 min data acquisition times, respectively.

Details

Language :
English
ISSN :
1361-6560
Volume :
56
Issue :
20
Database :
MEDLINE
Journal :
Physics in medicine and biology
Publication Type :
Academic Journal
Accession number :
21965275
Full Text :
https://doi.org/10.1088/0031-9155/56/20/013