Back to Search
Start Over
Circumferential evaluation of the neointima by optical coherence tomography after ABSORB bioresorbable vascular scaffold implantation: can the scaffold cap the plaque?
- Source :
-
Atherosclerosis [Atherosclerosis] 2012 Mar; Vol. 221 (1), pp. 106-12. Date of Electronic Publication: 2011 Dec 13. - Publication Year :
- 2012
-
Abstract
- Objective: To quantify the circumferential healing process at 6 and 12 months following scaffold implantation.<br />Background: The healing process following stent implantation consists of tissue growing on the top of and in the space between each strut. With the ABSORB bioresorbable vascular scaffold (BVS), the outer circumference of the scaffold is detectable by optical coherence tomography (OCT), allowing a more accurate and complete evaluation of the intra-scaffold neointima.<br />Methods: A total of 58 patients (59 lesions), who received an ABSORB BVS 1.1 implantation and a subsequent OCT investigation at 6 (n=28 patients/lesions) or 12 (n=30 patients with 31 lesions) months follow-up were included in the analysis. The thickness of the neointima was calculated circumferentially in the area between the abluminal side of the scaffold and the lumen by means of an automated detection algorithm. The symmetry of the neointima thickness in each cross section was evaluated as the ratio between minimum and maximum thickness.<br />Results: The neointima area was not different between 6 and 12 months follow-up (1.57±0.42 mm(2) vs. 1.64±0.77 mm(2); p=0.691). No difference was also found in the mean thickness of the neointima (median [IQR]) between the two follow-up time points (210 μm [180-260]) vs. 220 μm [150-260]; p=0.904). However, the symmetry of the neointima thickness was higher at 12 than at 6 months follow-up (0.23 [0.13-0.28] vs. 0.16 [0.08-0.21], p=0.019).<br />Conclusions: A circumferential evaluation of the healing process following ABSORB implantation is feasible, showing the formation of a neointima layer, that resembles a thick fibrous cap, known for its contribution to plaque stability.<br /> (Copyright © 2011 Elsevier Ireland Ltd. All rights reserved.)
- Subjects :
- Algorithms
Cardiovascular Agents administration & dosage
Coronary Artery Disease pathology
Delayed-Action Preparations
Endovascular Procedures adverse effects
Everolimus
Fibrosis
Humans
Image Processing, Computer-Assisted
Neointima etiology
Polyesters
Predictive Value of Tests
Sirolimus administration & dosage
Sirolimus analogs & derivatives
Time Factors
Treatment Outcome
Absorbable Implants
Coronary Artery Disease therapy
Coronary Vessels pathology
Endovascular Procedures instrumentation
Neointima pathology
Tissue Scaffolds
Tomography, Optical Coherence
Subjects
Details
- Language :
- English
- ISSN :
- 1879-1484
- Volume :
- 221
- Issue :
- 1
- Database :
- MEDLINE
- Journal :
- Atherosclerosis
- Publication Type :
- Academic Journal
- Accession number :
- 22209268
- Full Text :
- https://doi.org/10.1016/j.atherosclerosis.2011.12.008