320-detector row CT coronary angiography: effects of heart rate and heart rate variability on image quality, diagnostic accuracy and radiation exposure.
- Source :
-
The British journal of radiology [Br J Radiol] 2012 Aug; Vol. 85 (1016), pp. e388-94. Date of Electronic Publication: 2012 Feb 28. - Publication Year :
- 2012
-
Abstract
- Objectives: To evaluate the effects of heart rate and heart rate variability on image quality, patient dose and diagnostic accuracy of 320-detector row CT.<br />Methods: 94 patients were prospectively enrolled. Heart rate was defined as the mean value of different intervals elapsing between two consecutive R waves in an electrocardiogram (R-R intervals) and the heart rate variability was calculated as the standard deviation from the average heart rate. The image quality was evaluated by four grades, according to motion artefacts ("step artefacts" and "blurring artefacts"). The diagnostic accuracy was analysed in 43 patients who were scheduled for invasive coronary angiography (ICA). The coeffects of heart rate and heart rate variability on image quality, radiation dose and diagnostic accuracy were evaluated by multivariate regression.<br />Results: The mean image quality score was 1.2 ± 0.5 and the mean effective dose was 14.8 ± 9.8 mSv. The results showed that heart rate (74.0 ± 11.2 beats per minute) was the single factor influencing image quality (p<0.001) and radiation dose (p<0.001), while heart rate variability (3.7 ± 4.6) had no significant effect on them (p=0.16 and p=0.47, respectively). For 43 patients who underwent ICA, heart rate and heart rate variability showed no influence on the accuracy (p=0.17 and p=0.12, respectively). Overall sensitivity was 97.4% (37/38), specificity was 99.4% (351/353), positive predictive value was 94.9% (37/39) and negative predictive value was 99.7% (351/352).<br />Conclusion: 320-detector row CT, with improved longitudinal coverage of detector, resolves step artefact and high patient dose caused by irregular heart rate. However, it is still recommended to control heart rate to a lower level to eliminate blurring artefact and radiation dose.
- Subjects :
- Aged
Artifacts
Coronary Angiography standards
Dose-Response Relationship, Radiation
Electrocardiography
Female
Humans
Male
Middle Aged
Multidetector Computed Tomography standards
Prospective Studies
Radiation Dosage
Sensitivity and Specificity
Coronary Angiography methods
Coronary Artery Disease diagnostic imaging
Heart Rate
Multidetector Computed Tomography methods
Subjects
Details
- Language :
- English
- ISSN :
- 1748-880X
- Volume :
- 85
- Issue :
- 1016
- Database :
- MEDLINE
- Journal :
- The British journal of radiology
- Publication Type :
- Academic Journal
- Accession number :
- 22374285
- Full Text :
- https://doi.org/10.1259/bjr/92160185