Back to Search Start Over

Extraction of a strongly focusing He+ beam from three-stage concave electrodes for alpha particle measurement system in ITER.

Authors :
Kobuchi T
Sasao M
Kisaki M
Tsumori K
Tanaka N
Okamoto A
Kitajima S
Kaneko O
Shinto K
Wada M
Source :
The Review of scientific instruments [Rev Sci Instrum] 2012 Feb; Vol. 83 (2), pp. 02B120.
Publication Year :
2012

Abstract

A strongly focusing He(+) ion beam source equipped with concave multi-aperture electrodes was developed for production of He(-) through a charge exchange cell. The beam was extracted at a voltage less than 20 kV from 301 apertures distributed in an area of 100 mm φ, and focused at 750 mm distance. The beam current and the beam size of 2 A and 20 mm in diameter, respectively, were achieved with an arc power less than 10 kW. The optimum perveance was obtained at 0.02 A∕kV(1.5) at the beam energy less than 20 keV which is suitable for the conversion to He(-) in an alkali vapor cell.

Details

Language :
English
ISSN :
1089-7623
Volume :
83
Issue :
2
Database :
MEDLINE
Journal :
The Review of scientific instruments
Publication Type :
Academic Journal
Accession number :
22380277
Full Text :
https://doi.org/10.1063/1.3673630