Back to Search Start Over

Development and validation of an open screening method for diuretics, stimulants and selected compounds in human urine by UHPLC-HRMS for doping control.

Authors :
Girón AJ
Deventer K
Roels K
Van Eenoo P
Source :
Analytica chimica acta [Anal Chim Acta] 2012 Apr 06; Vol. 721, pp. 137-46. Date of Electronic Publication: 2012 Feb 09.
Publication Year :
2012

Abstract

A new doping control screening method for the analysis of diuretics and stimulants using ultra high pressure liquid chromatography-high resolution Orbitrap mass spectrometry has been developed. The screening was performed in full scan MS with scan-to-scan polarity switching which allowed to detect more than 120 target analytes. Sample preparation was limited to 10-fold dilution of the urine into the internal standard solution followed by injection. Total run time per sample was 10 min. Validation of the method yielded detection limits for diuretics between 25 and 250 ng mL(-1) and for stimulants between 5 and 500 ng mL(-1). The screening method has been implemented in routine doping control.<br /> (Copyright © 2012 Elsevier B.V. All rights reserved.)

Details

Language :
English
ISSN :
1873-4324
Volume :
721
Database :
MEDLINE
Journal :
Analytica chimica acta
Publication Type :
Academic Journal
Accession number :
22405312
Full Text :
https://doi.org/10.1016/j.aca.2012.02.002