The early inflammatory response in a mini-cardiopulmonary bypass system: a prospective randomized study.

Authors :
Kiaii B
Fox S
Swinamer SA
Rayman R
Higgins J
Cleland A
Fernandes P
MacDonald J
Dobkowski WB
Stitt LW
Novick RJ
Singh B
Bureau Y
Summers K
Source :
Innovations (Philadelphia, Pa.) [Innovations (Phila)] 2012 Jan-Feb; Vol. 7 (1), pp. 23-32.
Publication Year :
2012

Abstract

Objective: The aim of this study was to compare the early systemic inflammatory response of the Resting Heart System (RHS; Medtronic, Minneapolis, MN USA), a miniaturized cardiopulmonary bypass (CPB) system, with two groups using a standard extracorporeal circulation system during on-pump coronary artery bypass grafting (CABG) surgery.<br />Methods: A total of 60 consecutive patients requiring CABG were prospectively randomized to undergo on-pump CABG using conventional CPB without cardiotomy suction (group A), conventional CPB with cardiotomy suction (group B), or the RHS (group C). Blood samples were collected at five time points: immediately before CPB, 30 minutes into CPB, immediately at the end of CPB, 30 minutes post-CPB, and 1 hour post-CPB. Inflammation was analyzed by changes in (a) levels of plasma proteins, including inflammatory cytokines (interleukin-6 [IL-6], IL-10, and tumor necrosis factor-α), chemokines (IL-8, monokine induced by interferon-γ, monocyte chemotactic protein-1, regulated on activation normal T cell expressed and secreted, and interferon-inducible protein-10), and acute phase proteins (C-reactive protein and complement protein 3); (b) biochemical variables (cardiac troponin I, hematocrit, and immunoglobulin G); and (c) cell numbers (leukocytes, neutrophils, and thrombocytes).<br />Results: The RHS showed more delayed secretion of the cytokines tumor necrosis factor-α and IL-10, chemokines monokine induced by interferon-γ (P < 0.001); IL-8, and interferon-inducible protein-10; and complement protein 3 than conventional CPB systems did. Median thrombocyte numbers were higher in the RHS group. Levels of cardiac troponin I, monocyte chemotactic protein-1, and IL-6 were lower in both the RHS and conventional CPB without suction than with suction. Levels of C-reactive protein and regulated on activation normal T cell expressed and secreted, plus leukocyte and neutrophil numbers, were similar in all groups.<br />Conclusions: The Medtronic RHS may induce less systemic inflammation than conventional CPB systems, particularly when cardiotomy suction was used, but it did not result in improved clinical benefit.

Details

Language :
English
ISSN :
1559-0879
Volume :
7
Issue :
1
Database :
MEDLINE
Journal :
Innovations (Philadelphia, Pa.)
Publication Type :
Academic Journal
Accession number :
22576032
Full Text :
https://doi.org/10.1097/IMI.0b013e3182552ade