Back to Search
Start Over
The SILVER (Silver Impregnated Line Versus EVD Randomized trial): a double-blind, prospective, randomized, controlled trial of an intervention to reduce the rate of external ventricular drain infection.
- Source :
-
Neurosurgery [Neurosurgery] 2012 Aug; Vol. 71 (2), pp. 394-403; discussion 403-4. - Publication Year :
- 2012
-
Abstract
- Background: Cerebrospinal fluid (CSF) infections associated with external ventricular drain (EVD) placement attract major consequences. Silver impregnation of catheters attempts to reduce infection.<br />Objective: To assess the efficacy of silver catheters against CSF infection.<br />Methods: We performed a randomized, controlled trial involving 2 neurosurgical centers (June 2005 to September 2009). A total of 356 patients requiring an EVD were assessed for eligibility; 325 patients were enrolled and randomized (167 plain, 158 silver); 278 patients were analyzed (140 plain, 138 silver). The primary outcome measure was CSF infection as defined by organisms seen on Gram stain or isolated by culture. Secondary outcome measures included ventriculoperitoneal (VP) shunting.<br />Results: There was a significant difference in infection risk between the 2 study arms: 21.4% (30/140) for plain catheters vs 12.3% (17/138) for silver catheters (P = .0427; 95% confidence interval [CI]: 1.015-3.713). Patients who had an EVD infection had more than double the risk of requiring a VP shunt compared with patients without an EVD infection (45.7% [21/46] vs 19.7% [45/229], respectively, P = .0002; 95% CI: 1.766-6.682). There was also a significant difference in VP shunt risk with infection: plain (55.2%; 16/29) vs the silver arm (29.4%; 5/17); P = .0244 (95% CI: 1.144-11.695). A multivariate analysis demonstrated that infection risk was increased by duration of EVD placement (odds ratio: 1.160), spontaneous intracranial hemorrhage (odds ratio 4.958) and decreased by silver catheters (odds ratio: 0.423).<br />Conclusion: The study provides Class I evidence that silver-impregnated catheters reduce CSF infection.
- Subjects :
- Adolescent
Adult
Aged
Aged, 80 and over
Cerebrospinal Fluid Shunts statistics & numerical data
Coated Materials, Biocompatible chemistry
Coated Materials, Biocompatible therapeutic use
Comorbidity
Double-Blind Method
Drainage instrumentation
Drainage statistics & numerical data
Humans
Male
Middle Aged
Prevalence
Risk Factors
Silver chemistry
Treatment Outcome
United Kingdom epidemiology
Young Adult
Cerebral Ventricles surgery
Cerebrospinal Fluid Shunts instrumentation
Encephalitis epidemiology
Encephalitis prevention & control
Prosthesis-Related Infections epidemiology
Prosthesis-Related Infections prevention & control
Silver therapeutic use
Subjects
Details
- Language :
- English
- ISSN :
- 1524-4040
- Volume :
- 71
- Issue :
- 2
- Database :
- MEDLINE
- Journal :
- Neurosurgery
- Publication Type :
- Academic Journal
- Accession number :
- 22811084
- Full Text :
- https://doi.org/10.1227/NEU.0b013e318257bebb