Back to Search
Start Over
Clinical validation of dried blood spot sampling in therapeutic drug monitoring of ciclosporin A in allogeneic stem cell transplant recipients: direct comparison between capillary and venous sampling.
- Source :
-
Therapeutic drug monitoring [Ther Drug Monit] 2013 Feb; Vol. 35 (1), pp. 92-5. - Publication Year :
- 2013
-
Abstract
- Background: The immunosuppressive drug ciclosporin A has a narrow therapeutic window and a large inter- and intraindividual pharmacokinetic variability. Therapeutic drug monitoring of ciclosporin is usually performed in ethylenediaminetetraacetic acid blood, obtained by venous sampling. Dried blood spot sampling (DBS) could be a useful alternative sampling method, which also easily allows multiple sampling, for example, for obtaining area under the curve. With DBS, capillary blood is obtained from a finger prick with an automatic lancet by the patients themselves, and the drop of blood is applied to sampling paper. This may limit the number and duration of hospital visits for these patients.<br />Methods: We describe a validation study in which venous and finger prick blood samples were collected at the same time. Venous sampling was performed by venipuncture, and the ethylenediaminetetraacetic acid blood samples were collected and stored at 4°C until analysis. Finger prick blood samples were collected using an automatic lancing device. The volume of the blood drops of patients was approximately 30 μL, and blood spots of about 10-mm diameter were produced. Paper disks with a diameter of 8 mm were punched out with an electromagnetic-driven hole puncher. DBS was compared with the routine assay in venous blood. The study population consisted of adult patients (18 years or older) who were treated with ciclosporin A and routinely monitored for adequate blood concentrations.<br />Results: Thirty-eight duplicate dried blood spots and venous samples were studied. Using weighted Deming regression, the slope was 1.01 with a standard error of 0.03 associated with an intercept of -9.0 (standard error = 5.9). These results indicate that there is no significant difference between the 2 sampling methods. For the medical decision level of 300 mcg/L, the bias was -4.7 mcg/L with a 95% confidence interval of -19.2 to 9.8 mcg/L. The Altman-Bland plot showed no difference between the 2 sampling methods.<br />Conclusions: Our results demonstrate that DBS is a valid alternative for conventional venous sampling in allogeneic stem cell transplant recipients.
- Subjects :
- Adolescent
Drug Monitoring methods
Edetic Acid chemistry
Fingers blood supply
Humans
Immunosuppressive Agents therapeutic use
Phlebotomy methods
Stem Cell Transplantation methods
Transplantation
Transplantation, Homologous methods
Capillaries chemistry
Cyclosporine blood
Cyclosporine therapeutic use
Dried Blood Spot Testing methods
Immunosuppressive Agents blood
Veins chemistry
Subjects
Details
- Language :
- English
- ISSN :
- 1536-3694
- Volume :
- 35
- Issue :
- 1
- Database :
- MEDLINE
- Journal :
- Therapeutic drug monitoring
- Publication Type :
- Academic Journal
- Accession number :
- 23296096
- Full Text :
- https://doi.org/10.1097/FTD.0b013e31827d76ce