Back to Search Start Over

Errors in anti-D immunoglobulin administration: retrospective analysis of 15 years of reports to the UK confidential haemovigilance scheme.

Authors :
Bolton-Maggs PH
Davies T
Poles D
Cohen H
Source :
BJOG : an international journal of obstetrics and gynaecology [BJOG] 2013 Jun; Vol. 120 (7), pp. 873-8. Date of Electronic Publication: 2013 Mar 13.
Publication Year :
2013

Abstract

Objective: To highlight the errors associated with the use of anti-D immunoglobulin in RhD antigen-negative women, and their resultant clinical impact during and after pregnancy, and to suggest strategies to reduce these errors.<br />Design: Retrospective review of cumulative reporting to the UK confidential haemovigilance scheme, Serious Hazards of Transfusion (SHOT), between 1996 and 2011.<br />Setting: Obstetric departments in the UK.<br />Population: Mothers who require anti-D immunoglobulin to prevent RhD sensitisation during pregnancy or after birth.<br />Methods: Hospital transfusion teams reported adverse events to the SHOT database.<br />Main Outcome Measures: Reported number of events and their causes, and morbidity and mortality associated with errors.<br />Results: In 15 years of reporting, SHOT haemovigilance has shown a total of 1211 errors related to the administration of anti-D immunoglobulin, particularly regarding omission or late administration (157/249 or 63% reported in 2011). Anti-D immunoglobulin errors comprised 13.7% (249/1815) of all SHOT reports in 2011. Failure to recognise women who already have RhD sensitisation occurred in 19 cases, and was followed by suboptimal monitoring of the pregnancy. Nine of the infants suffered haemolytic disease of the fetus and newborn (HDFN): one resulted in neonatal death and three required red cell transfusion.<br />Conclusions: Babies as well as their mothers remain at risk from avoidable errors. More active attention at national and local levels to further education and training, particularly for midwives, is an absolute necessity. We recommend the use of a SHOT-devised anti-D administration flowchart, adapted locally into a checklist, to help reduce errors.<br /> (© 2013 The Authors BJOG An International Journal of Obstetrics and Gynaecology © 2013 RCOG.)

Details

Language :
English
ISSN :
1471-0528
Volume :
120
Issue :
7
Database :
MEDLINE
Journal :
BJOG : an international journal of obstetrics and gynaecology
Publication Type :
Academic Journal
Accession number :
23489292
Full Text :
https://doi.org/10.1111/1471-0528.12175