Low-dose dual-source CT angiography with iterative reconstruction for coronary artery stent evaluation.
- Source :
-
JACC. Cardiovascular imaging [JACC Cardiovasc Imaging] 2013 Apr; Vol. 6 (4), pp. 458-65. Date of Electronic Publication: 2013 Mar 14. - Publication Year :
- 2013
-
Abstract
- Objectives: The purpose of this study was to evaluate the image quality and diagnostic accuracy of very low-dose, dual-source computed tomography (DSCT) angiography for the evaluation of coronary stents.<br />Background: Iterative reconstruction (IR) leads to substantial reduction of image noise and hence permits the use of very low-dose data acquisition protocols in coronary computed tomography angiography.<br />Methods: Fifty symptomatic patients with 87 coronary stents (diameter 3.0 ± 0.4 mm) underwent coronary DSCT angiography (heart rate, 60 ± 6 beats/min; prospectively electrocardiography-triggered axial acquisition; 80 kV, 165 mA, 2 × 128 × 0.6-mm collimation; 60 ml of contrast at 6 ml/s) before invasive coronary angiography. DSCT images were reconstructed using both standard filtered back projection and a raw data-based IR algorithm (SAFIRE, Siemens Healthcare, Forchheim, Germany). Subjective image quality (4-point scale from 0 [nondiagnostic] to 3 [excellent image quality]), image noise, contrast-to-noise ratio as well as the presence of in-stent stenosis >50% were independently determined by 2 observers.<br />Results: The median dose-length product was 23.0 (22.0; 23.0) mGy · cm (median estimated effective dose of 0.32 [0.31; 0.32] mSv). IR led to significantly improved image quality compared with filtered back projection (image quality score, 1.8 ± 0.6 vs. 1.5 ± 0.5, p < 0.05; image noise, 70 Hounsfield units [62; 80 Hounsfield units] vs. 96 Hounsfield units [82; 113 Hounsfield units], p < 0.001; contrast-to-noise ratio, 11.0 [9.6; 12.4] vs. 8.0 [6.2; 9.3], p < 0.001). To detect significant coronary stenosis in filtered back projection reconstructions, the sensitivity, specificity, positive predictive value, and negative predictive value were 97% (32 of 33), 53% (9 of 17), 80% (32 of 40), and 90% (9 of 10) per patient, respectively; 89% (43 of 48), 79% (120 of 152), 57% (42 of 74), and 96% (121 of 126) per vessel, respectively; and 85% (12 of 14), 69% (51 of 73), 32% (11 of 34), and 96% (51 of 53) per stent, respectively. In reconstructions obtained by IR, the corresponding values were 100% (33 of 33), 65% (11 of 17), 85% (33 of 39), and 100% (11 of 11) per patient, respectively; 96% (46 of 48), 84% (129 of 152), 66% (47 of 71), and 98% (127 of 129) per vessel, respectively; and 100% (14 of 14), 75% (55 of 73), 44% (14 of 32), and 100% (55 of 55) per stent, respectively. These differences were not significant.<br />Conclusions: In selected patients, prospectively electrocardiography-triggered image acquisition with 80-kV tube voltage and low current in combination with IR permits the evaluation of patients with implanted coronary artery stents with reasonable diagnostic accuracy at very low radiation exposure.<br /> (Copyright © 2013 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.)
- Subjects :
- Aged
Algorithms
Coronary Restenosis etiology
Electrocardiography
Feasibility Studies
Female
Humans
Male
Middle Aged
Observer Variation
Percutaneous Coronary Intervention adverse effects
Predictive Value of Tests
Prosthesis Design
Reproducibility of Results
Treatment Outcome
Cardiac-Gated Imaging Techniques methods
Coronary Angiography methods
Coronary Restenosis diagnostic imaging
Coronary Vessels diagnostic imaging
Percutaneous Coronary Intervention instrumentation
Radiation Dosage
Radiographic Image Interpretation, Computer-Assisted
Stents
Tomography, X-Ray Computed
Subjects
Details
- Language :
- English
- ISSN :
- 1876-7591
- Volume :
- 6
- Issue :
- 4
- Database :
- MEDLINE
- Journal :
- JACC. Cardiovascular imaging
- Publication Type :
- Academic Journal
- Accession number :
- 23498678
- Full Text :
- https://doi.org/10.1016/j.jcmg.2012.10.023