Back to Search Start Over

Early diagnosis of myocardial infarction using absolute and relative changes in cardiac troponin concentrations.

Authors :
Irfan A
Reichlin T
Twerenbold R
Meister M
Moehring B
Wildi K
Bassetti S
Zellweger C
Gimenez MR
Hoeller R
Murray K
Sou SM
Mueller M
Mosimann T
Reiter M
Haaf P
Ziller R
Freidank H
Osswald S
Mueller C
Source :
The American journal of medicine [Am J Med] 2013 Sep; Vol. 126 (9), pp. 781-788.e2. Date of Electronic Publication: 2013 Jul 18.
Publication Year :
2013

Abstract

Background: Absolute changes in high-sensitivity cardiac troponin T (hs-cTnT) seem to have higher diagnostic accuracy in the early diagnosis of acute myocardial infarction compared with relative changes. It is unknown whether the same applies to high-sensitivity cardiac troponin I (hs-cTnI) assays and whether the combination of absolute and relative change might further increase accuracy.<br />Methods: In a prospective, international multicenter study, high-sensitivity cardiac troponin (hs-cTn) was measured with 3 novel assays (hs-cTnT, Roche Diagnostics Corp, Indianapolis, Ind; hs-cTnI, Beckman Coulter Inc, Brea, Calif; hs-cTnI, Siemens, Munich, Germany) in a blinded fashion at presentation and after 1 and 2 hours in a blinded fashion in 830 unselected patients with suspected acute myocardial infarction. The final diagnosis was adjudicated by 2 independent cardiologists.<br />Results: The area under the receiver operating characteristic curve for diagnosing acute myocardial infarction was significantly higher for 1- and 2-hour absolute versus relative hs-cTn changes for all 3 assays (P < .001). The area under the receiver operating characteristic curve of the combination of 2-hour absolute and relative change (hs-cTnT 0.98 [95% confidence interval {CI}, 0.97-0.99]; hs-cTnI, Beckman Coulter Inc, 0.97 [95% CI, 0.96-0.99]; hs-cTnI, Siemens, 0.96 [95% CI, 0.93-0.99]) were high and provided some benefit compared with the use of absolute change alone for hs-cTnT, but not for the hs-cTnI assays. Reclassification analysis confirmed the superiority of absolute changes versus relative changes.<br />Conclusions: Absolute changes seem to be the preferred metrics for both hs-cTnT and hs-cTnI in the early diagnosis of acute myocardial infarction. The combination of absolute and relative changes provides a small added value for hs-cTnT, but not for hs-cTnI.<br /> (Copyright © 2013 Elsevier Inc. All rights reserved.)

Details

Language :
English
ISSN :
1555-7162
Volume :
126
Issue :
9
Database :
MEDLINE
Journal :
The American journal of medicine
Publication Type :
Academic Journal
Accession number :
23870791
Full Text :
https://doi.org/10.1016/j.amjmed.2013.02.031