Back to Search Start Over

Validation study of the accuracy of echocardiographic measurements of systemic blood flow volume in newborn infants.

Authors :
Ficial B
Finnemore AE
Cox DJ
Broadhouse KM
Price AN
Durighel G
Ekitzidou G
Hajnal JV
Edwards AD
Groves AM
Source :
Journal of the American Society of Echocardiography : official publication of the American Society of Echocardiography [J Am Soc Echocardiogr] 2013 Dec; Vol. 26 (12), pp. 1365-71. Date of Electronic Publication: 2013 Sep 26.
Publication Year :
2013

Abstract

Background: The echocardiographic assessment of circulatory function in sick newborn infants has the potential to improve patient care. However, measurements are prone to error and have not been sufficiently validated. Phase-contrast magnetic resonance imaging (MRI) provides highly validated measures of blood flow and has recently been applied to the newborn population. The aim of this study was to validate measures of left ventricular output and superior vena caval flow volume in newborn infants.<br />Methods: Echocardiographic and MRI assessments were performed within 1 working day of each other in a cohort of newborn infants.<br />Results: Examinations were performed in 49 infants with a median corrected gestational age at scan of 34.43 weeks (range, 27.43-40 weeks) and a median weight at scan of 1,880 g (range, 660-3,760 g). Echocardiographic assessment of left ventricular output showed a strong correlation with MRI assessment (R(2) = 0.83; mean bias, -9.6 mL/kg/min; limits of agreement, -79.6 to +60.0 mL/kg/min; repeatability index, 28.2%). Echocardiographic assessment of superior vena caval flow showed a poor correlation with MRI assessment (R(2) = 0.22; mean bias, -13.7 mL/kg/min; limits of agreement, -89.1 to +61.7 mL/kg/min; repeatability index, 68.0%). Calculating superior vena caval flow volume from an axial area measurement and applying a 50% reduction to stroke distance to compensate for overestimation gave a slightly improved correlation with MRI (R(2) = 0.29; mean bias, 2.6 mL/kg/min; limits of agreement, -53.4 to +58.6 mL/kg/min; repeatability index, 54.5%).<br />Conclusions: Echocardiographic assessment of left ventricular output appears relatively robust in newborn infant. Echocardiographic assessment of superior vena caval flow is of limited accuracy in this population, casting doubt on the utility of the measurement for diagnostic decision making.<br /> (Copyright © 2013 American Society of Echocardiography. Published by Mosby, Inc. All rights reserved.)

Details

Language :
English
ISSN :
1097-6795
Volume :
26
Issue :
12
Database :
MEDLINE
Journal :
Journal of the American Society of Echocardiography : official publication of the American Society of Echocardiography
Publication Type :
Academic Journal
Accession number :
24075229
Full Text :
https://doi.org/10.1016/j.echo.2013.08.019