Back to Search Start Over

Development of a multi-channel piezoelectric acoustic sensor based on an artificial basilar membrane.

Authors :
Jung Y
Kwak JH
Lee YH
Kim WD
Hur S
Source :
Sensors (Basel, Switzerland) [Sensors (Basel)] 2013 Dec 20; Vol. 14 (1), pp. 117-28. Date of Electronic Publication: 2013 Dec 20.
Publication Year :
2013

Abstract

In this research, we have developed a multi-channel piezoelectric acoustic sensor (McPAS) that mimics the function of the natural basilar membrane capable of separating incoming acoustic signals mechanically by their frequency and generating corresponding electrical signals. The McPAS operates without an external energy source and signal processing unit with a vibrating piezoelectric thin film membrane. The shape of the vibrating membrane was chosen to be trapezoidal such that different locations of membrane have different local resonance frequencies. The length of the membrane is 28 mm and the width of the membrane varies from 1 mm to 8 mm. Multiphysics finite element analysis (FEA) was carried out to predict and design the mechanical behaviors and piezoelectric response of the McPAS model. The designed McPAS was fabricated with a MEMS fabrication process based on the simulated results. The fabricated device was tested with a mouth simulator to measure its mechanical and piezoelectrical frequency response with a laser Doppler vibrometer and acoustic signal analyzer. The experimental results show that the as fabricated McPAS can successfully separate incoming acoustic signals within the 2.5 kHz-13.5 kHz range and the maximum electrical signal output upon acoustic signal input of 94 dBSPL was 6.33 mVpp. The performance of the fabricated McPAS coincided well with the designed parameters.

Details

Language :
English
ISSN :
1424-8220
Volume :
14
Issue :
1
Database :
MEDLINE
Journal :
Sensors (Basel, Switzerland)
Publication Type :
Academic Journal
Accession number :
24361926
Full Text :
https://doi.org/10.3390/s140100117