Back to Search
Start Over
Absolute survival after cardiac resynchronization therapy according to baseline QRS duration: a multinational 10-year experience: data from the Multicenter International CRT Study.
- Source :
-
American heart journal [Am Heart J] 2014 Feb; Vol. 167 (2), pp. 203-209.e1. Date of Electronic Publication: 2013 Nov 04. - Publication Year :
- 2014
-
Abstract
- Background: In the major trials of cardiac resynchronization therapy (CRT), the survival benefit of the therapy, relative to control subjects, increases with QRS duration. In the non-CRT heart failure population, however, a wide QRS duration is associated with a shorter survival. Relative survival benefit from a therapy, however, is not synonymous with a longer absolute survival. We sought to determine whether baseline QRS duration relates to the absolute survival after CRT.<br />Methods and Results: In this prospective, longitudinal, observational study, 3,319 consecutive patients undergoing CRT (QRS 120-149 ms 26%, QRS 150-199 ms 58%, and QRS ≥200 ms 16%) were assessed in relation to mortality over 10 years. Overall mortality rates (per 100 patient-years) were 9.2%, 9.3%, and 13.3% in the 3 groups, respectively (all P < .001). Cardiac mortality rates were 6.2, 6.0, and 9.9 per 100 patient-years, respectively (all P < .001). Compared with the QRS 120-149 ms group, cardiac mortality was highest in the QRS ≥200 ms group (hazard ratio [HR] 1.72 [95% CI 1.35-2.19], P < .001), independent of age, gender, New York Heart Association class, presence of atrial fibrillation, heart failure etiology, and left ventricular ejection fraction. Median survival after CRT was longest in patients with a width of QRS 120-149 ms and shortest in patients with a QRS ≥200 ms (P < .001). In multivariable analyses, a QRS ≥200 ms emerged as a powerful independent predictor of both overall (HR 1.44 [95% CI 1.07-1.94], P = .017) and cardiac mortality (HR 1.59 [95% CI 1.14-2.24], P = .007).<br />Conclusions: At long-term follow-up, absolute overall and cardiac survival after CRT is similar in patients with a preimplant QRS duration of 120 to 149 ms and 150 to 199 ms but markedly shorter in patients with a QRS ≥200 ms.<br /> (© 2014.)
- Subjects :
- Aged
Asia epidemiology
Cause of Death trends
Europe epidemiology
Female
Follow-Up Studies
Heart Failure physiopathology
Heart Failure therapy
Humans
Male
North America epidemiology
Prospective Studies
Stroke Volume
Survival Rate trends
Time Factors
Treatment Outcome
Ventricular Function, Left physiology
Cardiac Resynchronization Therapy methods
Defibrillators, Implantable
Electrocardiography
Heart Failure mortality
Subjects
Details
- Language :
- English
- ISSN :
- 1097-6744
- Volume :
- 167
- Issue :
- 2
- Database :
- MEDLINE
- Journal :
- American heart journal
- Publication Type :
- Academic Journal
- Accession number :
- 24439981
- Full Text :
- https://doi.org/10.1016/j.ahj.2013.10.017