Near-infrared imaging of brain tumors using the Tumor Paint BLZ-100 to achieve near-complete resection of brain tumors.

Authors :
Butte PV
Mamelak A
Parrish-Novak J
Drazin D
Shweikeh F
Gangalum PR
Chesnokova A
Ljubimova JY
Black K
Source :
Neurosurgical focus [Neurosurg Focus] 2014 Feb; Vol. 36 (2), pp. E1.
Publication Year :
2014

Abstract

Object: The intraoperative clear delineation between brain tumor and normal tissue in real time is required to ensure near-complete resection without damaging the nearby eloquent brain. Tumor Paint BLZ-100, a tumor ligand chlorotoxin (CTX) conjugated to indocyanine green (ICG), has shown potential to be a targeted contrast agent. There are many infrared imaging systems in use, but they are not optimized to the low concentration and amount of ICG. The authors present a novel proof-of-concept near-infrared (NIR) imaging system using a standard charge-coupled device (CCD) camera for visualizing low levels of ICG attached to the tumors. This system is small, inexpensive, and sensitive. The imaging system uses a narrow-band laser at 785 nm and a notch filter in front of the sensor at the band. The camera is a 2-CCD camera, which uses identical CCDs for both visible and NIR light.<br />Methods: The NIR system is tested with serial dilution of BLZ-100 from 1 μM to 50 pM in 5% Intralipid solution while the excitation energy is varied from 5 to 40 mW/cm(2). The analog gain of the CCD was changed from 0, 6, and 12 dB to determine the signal-to-noise ratio. In addition to the Intralipid solution, BLZ-100 was injected 48 hours before euthanizing the mice that were implanted with the human glioma cell line. The brain was removed and imaged using the NIR imaging system.<br />Results: The authors' results show that the NIR imaging system using a standard CCD is able to visualize the ICG down to 50 nM of concentration with a high signal-to-noise ratio. The preliminary experiment on human glioma implanted in mouse brains demonstrated that BLZ-100 has a high affinity for glioma compared with normal brain tissue. Additionally, the results show that NIR excitation is able to penetrate deeply and has a potential to visualize metastatic lesions that are separate from the main tumor.<br />Conclusions: The authors have seen that BLZ-100 has a very high affinity toward human gliomas. They also describe a small, cost-effective, and sensitive NIR system for visualizing brain tumors tagged using BLZ-100. The authors hope that the use of BLZ-100 along with NIR imaging will be useful to delineate the brain tumors in real time and assist surgeons in near-complete tumor removal to increase survival and reduce neurological deficits.

Details

Language :
English
ISSN :
1092-0684
Volume :
36
Issue :
2
Database :
MEDLINE
Journal :
Neurosurgical focus
Publication Type :
Academic Journal
Accession number :
24484247
Full Text :
https://doi.org/10.3171/2013.11.FOCUS13497