Back to Search Start Over

Monochromatic verification of high-contrast imaging with an occulter.

Authors :
Sirbu D
Kasdin NJ
Vanderbei RJ
Source :
Optics express [Opt Express] 2013 Dec 30; Vol. 21 (26), pp. 32234-53.
Publication Year :
2013

Abstract

One of the most promising concepts of starlight suppression for direct imaging of exoplanets is flying a specially-shaped external occulter in formation with a space telescope. Here we present contrast performance verification of an occulter design scaled to laboratory-size using Fresnel numbers corresponding to the space design. Experimental design innovations include usage of an expanding beam to minimize phase aberrations, and an outer ring to minimize hard-edge diffraction effects. The apodizing performance of the optimized occulter edge is compared with a baseline case of a circular occulter and shown to result in contrast improvements. Experimental results in red monochromatic light show that the achieved laboratory contrast exceeds ten orders of magnitude, but with differences from the theoretical diffraction analysis limited by specular reflection from the mask edges.

Details

Language :
English
ISSN :
1094-4087
Volume :
21
Issue :
26
Database :
MEDLINE
Journal :
Optics express
Publication Type :
Academic Journal
Accession number :
24514818
Full Text :
https://doi.org/10.1364/OE.21.032234