Back to Search
Start Over
Functional magnetic resonance cholangiography with Gd-EOB-DTPA: a study in healthy volunteers.
- Source :
-
Magnetic resonance imaging [Magn Reson Imaging] 2014 May; Vol. 32 (4), pp. 385-91. Date of Electronic Publication: 2014 Jan 13. - Publication Year :
- 2014
-
Abstract
- Purpose: To describe the patterns of bile distribution in the biliary tree, duodenum, jejunum, and stomach, and to determine the gallbladder ejection fraction (GBEF) by using functional magnetic resonance cholangiography (MRC) with gadolinium-ethoxybenzyl-diethylenetriamine penta-acetic acid (Gd-EOB-DTPA) in healthy volunteers.<br />Materials and Methods: Forty subjects were included in this study. After conventional MRC, pre-fatty meal MRC (PRFM) was obtained at 30, 40, 50, and 60min after contrast agent injection. Then, post-fatty meal MRC (POFM) was obtained every 10min for 1h. We assessed the PRFM and POFM for opacification of contrast agent in the first- and second-order intrahepatic ducts (IHDs) and the common bile duct (CBD). Contrast agent opacification in the cystic duct was assessed, and the percentage volume of contrast agent filling in the gallbladder (GB) was calculated on PRFM. We calculated the GBEF and assessed the presence of contrast agent in the GB, duodenum, jejunum, and stomach.<br />Results: Thirty-six (90%) subjects showed grade 3 CBD opacification (visible contrast and well-defined bile duct border) on 60-min PRFM. Thirty-four (85%) subjects showed grade 3 first-order IHD opacification on 60-min PRFM. All (100%) subjects showed cystic duct opacification of contrast agent, and the average percentage volume of contrast agent filling in the GB was 68.81%±16.84% on 60-min PRFM. The GBEF at 30-min POFM was 35.00%±18.26%. Ten (25%) subjects had no contrast agent in the stomach and small bowel on all PRFMs. Twelve (30%) subjects had contrast medium in the stomach on PRFM and/or POFM.<br />Conclusions: Functional MRC with Gd-EOB-DTPA can allow determining the distribution of bile in the biliary tree and small intestine, as well as the GBEF.<br /> (Copyright © 2014 Elsevier Inc. All rights reserved.)
- Subjects :
- Adult
Contrast Media pharmacokinetics
Female
Healthy Volunteers
Humans
Male
Middle Aged
Reference Values
Reproducibility of Results
Sensitivity and Specificity
Biliary Tract physiology
Cholangiopancreatography, Magnetic Resonance methods
Gadolinium DTPA pharmacokinetics
Image Interpretation, Computer-Assisted methods
Magnetic Resonance Imaging methods
Subjects
Details
- Language :
- English
- ISSN :
- 1873-5894
- Volume :
- 32
- Issue :
- 4
- Database :
- MEDLINE
- Journal :
- Magnetic resonance imaging
- Publication Type :
- Academic Journal
- Accession number :
- 24529920
- Full Text :
- https://doi.org/10.1016/j.mri.2014.01.003