Back to Search Start Over

Closed loop direct adaptive inverse control for linear plants.

Authors :
Shafiq MA
Shafiq M
Ahmed N
Source :
TheScientificWorldJournal [ScientificWorldJournal] 2014 Jan 19; Vol. 2014, pp. 658497. Date of Electronic Publication: 2014 Jan 19 (Print Publication: 2014).
Publication Year :
2014

Abstract

In direct adaptive inverse control (DAIC), parameters of the controller are estimated directly in the feed-forward loop. In this paper, we propose a closed loop direct adaptive inverse control (CDAIC) scheme which improves tracking, error convergence, and disturbance rejection properties of DAIC. CDAIC is applicable to stable or stabilized, minimum or nonminimum phase linear plants. CDAIC and DAIC are compared using computer simulations for disturbance free and disturbed discrete type nonminimum phase linear plants. CDAIC shows better results compared to DAIC in terms of mean square tracking error and disturbance rejection.

Details

Language :
English
ISSN :
1537-744X
Volume :
2014
Database :
MEDLINE
Journal :
TheScientificWorldJournal
Publication Type :
Academic Journal
Accession number :
24574907
Full Text :
https://doi.org/10.1155/2014/658497