Back to Search
Start Over
Feasibility of non-invasive temperature estimation by the assessment of the average gray-level content of B-mode images.
- Source :
-
Ultrasonics [Ultrasonics] 2014 Aug; Vol. 54 (6), pp. 1692-702. Date of Electronic Publication: 2014 Mar 01. - Publication Year :
- 2014
-
Abstract
- This paper assesses the potential of the average gray-level (AVGL) from ultrasonographic (B-mode) images to estimate temperature changes in time and space in a non-invasive way. Experiments were conducted involving a homogeneous bovine muscle sample, and temperature variations were induced by an automatic temperature regulated water bath, and by therapeutic ultrasound. B-mode images and temperatures were recorded simultaneously. After data collection, regions of interest (ROIs) were defined, and the average gray-level variation computed. For the selected ROIs, the AVGL-Temperature relation were determined and studied. Based on uniformly distributed image partitions, two-dimensional temperature maps were developed for homogeneous regions. The color-coded temperature estimates were first obtained from an AVGL-Temperature relation extracted from a specific partition (where temperature was independently measured by a thermocouple), and then extended to the other partitions. This procedure aimed to analyze the AVGL sensitivity to changes not only in time but also in space. Linear and quadratic relations were obtained depending on the heating modality. We found that the AVGL-Temperature relation is reproducible over successive heating and cooling cycles. One important result was that the AVGL-Temperature relations extracted from one region might be used to estimate temperature in other regions (errors inferior to 0.5 °C) when therapeutic ultrasound was applied as a heating source. Based on this result, two-dimensional temperature maps were developed when the samples were heated in the water bath and also by therapeutic ultrasound. The maps were obtained based on a linear relation for the water bath heating, and based on a quadratic model for the therapeutic ultrasound heating. The maps for the water bath experiment reproduce an acceptable heating/cooling pattern, and for the therapeutic ultrasound heating experiment, the maps seem to reproduce temperature profiles consistent with the pressure field of the transducer, and in agreement with temperature maps developed by COMSOL®MultiPhysics simulations.<br /> (Copyright © 2014 Elsevier B.V. All rights reserved.)
- Subjects :
- Animals
Cattle
Equipment Design
Feasibility Studies
Hot Temperature
Image Processing, Computer-Assisted
Reproducibility of Results
Thermometry instrumentation
Transducers
Ultrasonic Therapy instrumentation
Ultrasonography
Water
Muscle, Skeletal diagnostic imaging
Thermometry methods
Ultrasonic Therapy methods
Subjects
Details
- Language :
- English
- ISSN :
- 1874-9968
- Volume :
- 54
- Issue :
- 6
- Database :
- MEDLINE
- Journal :
- Ultrasonics
- Publication Type :
- Academic Journal
- Accession number :
- 24630851
- Full Text :
- https://doi.org/10.1016/j.ultras.2014.02.021