Back to Search
Start Over
Measurement of meropenem concentration in different human biological fluids by ultra-performance liquid chromatography-tandem mass spectrometry.
- Source :
-
Analytical and bioanalytical chemistry [Anal Bioanal Chem] 2014 Aug; Vol. 406 (20), pp. 4997-5007. Date of Electronic Publication: 2014 May 31. - Publication Year :
- 2014
-
Abstract
- Meropenem is a broad-spectrum antibiotic, often used for the empirical treatment of infections in critically ill patients with acute kidney injury. Meropenem has clinically insignificant protein binding and, as a carbapenem antibiotic, shows time-dependent bacterial killing, meaning that the unbound or free antibiotic concentration in blood should be maintained above the minimal inhibitory concentration of the pathogen for at least 40 % of the dosing interval. We developed and validated simple chromatographic methods by ultra-performance liquid chromatography-tandem mass spectrometry to measure plasma, filtrate-dialysate, and urine concentrations of meropenem. Chromatographic separation was achieved using an Acquity(®) UPLC(®) BEH(TM) (2.1 × 100 mm id, 1.7 μm) reverse-phase C(18) column, with a water/acetonitrile linear gradient containing 0.1 % formic acid at a 0.4-mL/min flow rate. Meropenem and its internal standard (ertapenem) were detected by electrospray ionization mass spectrometry in positive ion multiple reaction monitoring mode. The limits of quantification were 0.27, 0.24, and 1.22 mg/L, and linearity was observed between 0.27-150, 0.24-150, and 1.22-2,000 mg/L for plasma, filtrate-dialysate, and urine samples, respectively. Coefficients of variation and relative biases were less than 13.5 and 8.0 % for all biological fluids. Recovery values were greater than 68.3 %. Evaluation of the matrix effect showed ion suppression for meropenem and ertapenem. No carry-over was observed. The validated methods are useful for both therapeutic drug monitoring and pharmacokinetic studies. It could be applied to daily clinical laboratory practice to measure the concentration of meropenem in plasma, filtrate-dialysate, and urine.
- Subjects :
- Acute Kidney Injury blood
Acute Kidney Injury drug therapy
Acute Kidney Injury urine
Anti-Bacterial Agents pharmacology
Critical Illness therapy
Humans
Meropenem
Renal Replacement Therapy
Sepsis blood
Sepsis drug therapy
Sepsis urine
Thienamycins pharmacology
Anti-Bacterial Agents analysis
Body Fluids chemistry
Chromatography, Liquid methods
Drug Monitoring
Spectrometry, Mass, Electrospray Ionization methods
Thienamycins analysis
Subjects
Details
- Language :
- English
- ISSN :
- 1618-2650
- Volume :
- 406
- Issue :
- 20
- Database :
- MEDLINE
- Journal :
- Analytical and bioanalytical chemistry
- Publication Type :
- Academic Journal
- Accession number :
- 24879538
- Full Text :
- https://doi.org/10.1007/s00216-014-7910-9