Abstract

Solid-phase radioimmunoassay methods for the uniform analysis in hemolyzed whole blood and urine of opiates, methamphetamine, cocaine, free morphine, and phencyclidine using Coat-A-Count kits available from Diagnostic Products Corporation were tested for cost effectiveness without compromising the reliability of the results. Results indicate these kits are superior in performance in cross-reactivity studies, noted particularly in the methamphetamine assay, labor conservation, and cost-effectiveness to double-antibody radioimmunoassay methods.

Details

Language :
English
ISSN :
0146-4760
Volume :
13
Issue :
5
Database :
MEDLINE
Journal :
Journal of analytical toxicology
Publication Type :
Academic Journal
Accession number :
2515393
Full Text :
https://doi.org/10.1093/jat/13.5.274