Mechanical aortic valve-on-valve replacement in previous Bentall procedure: an alternate technique.

Authors :
Manoly I
Krishnan M
Hoschtitzky JA
Hasan R
Source :
The Annals of thoracic surgery [Ann Thorac Surg] 2014 Sep; Vol. 98 (3), pp. e77-9.
Publication Year :
2014

Abstract

Acute aortic valve regurgitation due to thrombosed prosthetic valve can present as a surgical emergency. This article reports a successful and unusual management of a young pregnant female patient who presented with acute aortic valve regurgitation due to a thrombosed mechanical aortic valve. As the patient had previous multiple cardiac surgeries, the options were limited for repeat aortic valve or aortic root replacement. The patient had caesarean section followed by implantation of a mechanical valve-on-valve in a previously placed composite valved conduit. This technique may be useful for reoperative valve replacement in the setting of a prior mechanical Bentall patient.<br /> (Copyright © 2014 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.)