Back to Search Start Over

Comparison of robotic and manual persistent AF ablation using catheter contact force sensing: an international multicenter registry study.

Authors :
Ullah W
Hunter RJ
Haldar S
McLean A
Dhinoja M
Sporton S
Earley MJ
Lorgat F
Wong T
Schilling RJ
Source :
Pacing and clinical electrophysiology : PACE [Pacing Clin Electrophysiol] 2014 Nov; Vol. 37 (11), pp. 1427-35. Date of Electronic Publication: 2014 Sep 15.
Publication Year :
2014

Abstract

Background: Catheter-based contact force sensing (CFS) technology gives detailed information regarding contact between the catheter tip and myocardium. This may result in more effective ablation procedures. The primary objective of this study was comparison of remote robotic navigation (RRN) and Manual CFS ablation. The secondary objective was to compare CFS with non-CFS ablation for both navigation modes.<br />Methods: Prospective registries of consecutive cases undergoing their first ablation for persistent atrial fibrillation (AF) from six hospitals in the United Kingdom and South Africa were analyzed: 50 Manual/CFS and 50 RRN/CFS cases were included. Historical control non-CFS ablation patients were matched by propensity score, giving a total 200 patient cohort.<br />Results: RRN/CFS was associated with improved single procedure 1-year success rates (64% vs 36%, P = 0.01) and shorter fluoroscopy times (41% reduction, P < 0.0005) than Manual/CFS ablation, without any difference in procedure times (P = 0.8). The mean contact force was higher in RRN/CFS than Manual/CFS cases (16 [15-18 g] vs 13 [12-15 g], respectively, P = 0.003). Compared with non-CFS historical controls, CFS cases had higher 1-year success rates for RRN (64% vs 36%, P = 0.01), but not Manual ablation (36% vs 38%, P = 1). Procedure times were reduced for CFS cases (20%, P < 0.005 both navigation modes), as were fluoroscopy times (Manual: 43%, RRN 83%, P < 0.005 for both). There were no differences in rates of major or minor complications for either comparison (P > 0.5).<br />Conclusions: A combination of RRN and CFS is associated with improved success rates at 1 year and fluoroscopy times for persistent AF ablation, compared with Manual ablation and non-CFS RRN ablation.<br /> (©2014 Wiley Periodicals, Inc.)

Details

Language :
English
ISSN :
1540-8159
Volume :
37
Issue :
11
Database :
MEDLINE
Journal :
Pacing and clinical electrophysiology : PACE
Publication Type :
Academic Journal
Accession number :
25220575
Full Text :
https://doi.org/10.1111/pace.12501