Back to Search Start Over

[Ten years of early defibrillation: "Bochum against sudden cardiac death". Acceptance and critical analysis of using automated external defibrillators].

Authors :
Hanefeld C
Kloppe C
Breger W
Kloppe A
Mügge A
Wiemer M
Source :
Medizinische Klinik, Intensivmedizin und Notfallmedizin [Med Klin Intensivmed Notfmed] 2015 Apr; Vol. 110 (2), pp. 150-4. Date of Electronic Publication: 2014 Oct 29.
Publication Year :
2015

Abstract

Background: There is a comprehensive early defibrillation program in Bochum (Germany); since 2003 a total of 175 automated external defibrillators (AEDs) have been installed in urban areas by the city of Bochum and private companies. These were preferably installed in places with high foot traffic, e.g., public buildings, companies, and event/shopping centers. Approximately 15,000 laypeople who work in the vicinity of the AED locations were trained in the use of defibrillators and in basic resuscitation. In addition, rescue workers on fire trucks and medically trained personnel in physicians' medical practices were equipped as "first responders" with AEDs.<br />Results: After an initiation phase, all available information after each AED use since August 2004 has been collected by the project coordinator. During the period of data collection (August 2004 to August 2013), an AED was used in a total of 17 patients who had suffered sudden cardiac death (SCD) under the project in Bochum. Eleven patients had primary ventricular fibrillation (VF). Six of these survived without neurological deficit. In another 6 patients, a nondefibrillatable rhythm disorder was diagnosed. The AEDs are reliable and showed impeccable rhythm analysis before the instructions to provide any necessary shock.<br />Discussion: Compared to the number of existing units and an estimated number of 37-100 SCD/100,000, the use of the AEDs only 17 times appears relatively small. To improve the effectiveness of the AED program in Bochum, an analysis of the emergency service responses, which were necessary because of sudden circulatory collapse, is currently being performed. This will allow areas with an increased incidence of SCD to be identified and a plan for the strategic placement of AED and emergency services can be made.

Details

Language :
German
ISSN :
2193-6226
Volume :
110
Issue :
2
Database :
MEDLINE
Journal :
Medizinische Klinik, Intensivmedizin und Notfallmedizin
Publication Type :
Academic Journal
Accession number :
25348052
Full Text :
https://doi.org/10.1007/s00063-014-0436-2