Back to Search Start Over

Whole-body organ-level and kidney micro-dosimetric evaluations of (64)Cu-loaded HER2/ErbB2-targeted liposomal doxorubicin ((64)Cu-MM-302) in rodents and primates.

Authors :
Gaddy DF
Lee H
Zheng J
Jaffray DA
Wickham TJ
Hendriks BS
Source :
EJNMMI research [EJNMMI Res] 2015 Apr 14; Vol. 5, pp. 24. Date of Electronic Publication: 2015 Apr 14 (Print Publication: 2015).
Publication Year :
2015

Abstract

Background: Features of the tumor microenvironment influence the efficacy of cancer nanotherapeutics. The ability to directly radiolabel nanotherapeutics offers a valuable translational tool to obtain biodistribution and tumor deposition data, testing the hypothesis that the extent of delivery predicts therapeutic outcome. In support of a first in-human clinical trial with (64)Cu-labeled HER2-targeted liposomal doxorubicin ((64)Cu-MM-302), a preclinical dosimetric analysis was performed.<br />Methods: Whole-body biodistribution and pharmacokinetic data were obtained in mice that received (64)Cu-MM-302 and used to estimate absorbed radiation doses in normal human organs. PET/CT imaging revealed non-uniform distribution of (64)Cu signal in mouse kidneys. Kidney micro-dosimetry analysis was performed in mice and squirrel monkeys, using a physiologically based pharmacokinetic model to estimate the full dynamics of the (64)Cu signal in monkeys.<br />Results: Organ-level dosimetric analysis of mice receiving (64)Cu-MM-302 indicated that the heart was the organ receiving the highest radiation absorbed dose, due to extended liposomal circulation. However, PET/CT imaging indicated that (64)Cu-MM-302 administration resulted in heterogeneous exposure in the kidney, with a focus of (64)Cu activity in the renal pelvis. This result was reproduced in primates. Kidney micro-dosimetry analysis illustrated that the renal pelvis was the maximum exposed tissue in mice and squirrel monkeys, due to the highly concentrated signal within the small renal pelvis surface area.<br />Conclusions: This study was used to select a starting clinical radiation dose of (64)Cu-MM-302 for PET/CT in patients with advanced HER2-positive breast cancer. Organ-level dosimetry and kidney micro-dosimetry results predicted that a radiation dose of 400 MBq of (64)Cu-MM-302 should be acceptable in patients.

Details

Language :
English
ISSN :
2191-219X
Volume :
5
Database :
MEDLINE
Journal :
EJNMMI research
Publication Type :
Academic Journal
Accession number :
25918676
Full Text :
https://doi.org/10.1186/s13550-015-0096-0