Back to Search
Start Over
Feasibility Study of Pulsatile Left Ventricular Assist Device for Prolonged Ex Vivo Lung Perfusion.
- Source :
-
The Annals of thoracic surgery [Ann Thorac Surg] 2015 Jun; Vol. 99 (6), pp. 1961-7; discussion 1967-8. Date of Electronic Publication: 2015 Apr 25. - Publication Year :
- 2015
-
Abstract
- Background: Ex vivo lung perfusion (EVLP) has the potential to increase the donor pool for lung transplantation by facilitating resuscitation and extended evaluation of marginal organs. Current EVLP methodology employs continuous flow (CF) pumps that produce non-pulsatile EVLP hemodynamics. In this feasibility study, we tested the hypothesis that a pulsatile flow (PF) pump will provide better EVLP support than a CF pump through delivery of physiologic hemodynamics.<br />Methods: Porcine lungs were supported in an EVLP model by centrifugal CF (n = 3) or PF (n = 4) left ventricular assist devices. Lungs were ventilated at 4 to 5 mL/kg, 0.21 fraction of inspired oxygen (FiO2), and perfused with an acellular, albumin-based solution corrected for osmolarity, acid-base balance, and carbon dioxide pressure (≤20 hours at 30°C) for a minimum of 12 hours support. Prostaglandin E1 and 30% albumin were infused continuously. Hemodynamic, respiratory, and blood gas parameters were continuously monitored and digitally recorded hourly. Parenchymal biopsies were used for quantification of wet to dry weight ratio.<br />Results: All lungs maintained function in the EVLP circuit for a minimum of 12 hours (mean 14.7 ± 1 hours) and demonstrated minimal edema formation. The PF EVLP produced higher pulsatility as demonstrated by greater energy equivalent pressure and surplus hemodynamic energy compared with CF EVLP (p < 0.05). There were no statistically significant differences in pulmonary impedance, arterial partial pressure of oxygen/fraction of inspired oxygen, wet to dry weight ratio, and peak airway pressure between CF and PF EVLP.<br />Conclusions: The CF and PF EVLP systems successfully maintained lungs 12+ hours using a modified Steen perfusate (XVIVO Perfusion, Inc, Goteborg, Sweden); however, there were no statistically significant differences between CF and PF groups despite higher pulsatility, suggesting that PF may not offer immediate benefits over CF for prolonged ex vivo lung preservation.<br /> (Copyright © 2015 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.)
Details
- Language :
- English
- ISSN :
- 1552-6259
- Volume :
- 99
- Issue :
- 6
- Database :
- MEDLINE
- Journal :
- The Annals of thoracic surgery
- Publication Type :
- Academic Journal
- Accession number :
- 25921254
- Full Text :
- https://doi.org/10.1016/j.athoracsur.2015.02.087