Back to Search
Start Over
Use of an Intravascular Fluorescent Continuous Glucose Sensor in ICU Patients.
- Source :
-
Journal of diabetes science and technology [J Diabetes Sci Technol] 2015 Jul; Vol. 9 (4), pp. 762-70. Date of Electronic Publication: 2015 May 12. - Publication Year :
- 2015
-
Abstract
- Background: Hyperglycemia and hypoglycemia are associated with adverse clinical outcomes in intensive care patients. In product development studies at 4 ICUs, the safety and performance of an intravascular continuous glucose monitoring (IV-CGM) system was evaluated in 70 postsurgical patients.<br />Methods: The GluCath System (GluMetrics, Inc) used a quenched chemical fluorescence mechanism to optically measure blood glucose when deployed via a radial artery catheter or directly into a peripheral vein. Periodic ultrasound assessed blood flow and thrombus formation. Patient glucose levels were managed according to the standard of care and existing protocols at each site. Reference blood samples were acquired hourly and compared against prospectively calibrated sensor results.<br />Results: In all, 63 arterial sensors and 9 venous sensors were deployed in 70 patients. Arterial sensors did not interfere with invasive blood pressure monitoring, sampling or other aspects of patient care. A majority of venous sensors (66%) exhibited thrombus on ultrasound. In all, 89.4% (1383/1547) of arterial and 72.2% (182/252) of venous measurements met ISO15197:2003 criteria (within 20%), and 72.7% (1124/1547) of arterial and 56.3% (142/252) of venous measurements met CLSI POCT 12-A3 criteria (within 12.5%). The aggregate mean absolute relative difference (MARD) between the sensors and the reference was 9.6% for arterial and 14.2% for venous sensors.<br />Conclusions: The GluCath System exhibited acceptable accuracy when deployed in a radial artery for up to 48 hours in ICU patients after elective cardiac surgery. Accuracy of venous deployment was substantially lower with significant rates of intravascular thrombus observed using ultrasound.<br /> (© 2015 Diabetes Technology Society.)
- Subjects :
- Aged
Cardiac Surgical Procedures
Cohort Studies
Diabetes Mellitus blood
Diabetes Mellitus diagnosis
Female
Humans
Hyperglycemia blood
Hypoglycemia blood
Infusions, Intravenous
Intensive Care Units
Male
Middle Aged
Monitoring, Physiologic methods
Postoperative Period
Thrombosis diagnostic imaging
Ultrasonography
Blood Glucose analysis
Critical Care
Hyperglycemia diagnosis
Hypoglycemia diagnosis
Insulin Infusion Systems
Monitoring, Physiologic instrumentation
Subjects
Details
- Language :
- English
- ISSN :
- 1932-2968
- Volume :
- 9
- Issue :
- 4
- Database :
- MEDLINE
- Journal :
- Journal of diabetes science and technology
- Publication Type :
- Academic Journal
- Accession number :
- 25972280
- Full Text :
- https://doi.org/10.1177/1932296815585872