Feasibility study of high-resolution DCE-MRI for glomerular filtration rate (GFR) measurement in a routine clinical modal.
- Source :
-
Magnetic resonance imaging [Magn Reson Imaging] 2015 Oct; Vol. 33 (8), pp. 978-83. Date of Electronic Publication: 2015 May 21. - Publication Year :
- 2015
-
Abstract
- Dynamic contrast enhanced (DCE) MR renography has been identified as an interesting tool to determine single-kidney GFR. However, a fundamental issue for the applicability of MR-based estimate of single-kidney GFR is selecting a balance between spatial and temporal resolution of DCE-MRI data. The purpose is to assess the feasibility of GFR estimate from high-resolution (HR) dynamic contrast-enhanced (DCE) MRI in a routine clinical modal. Standard MR renography (2.4s/phase, total 4min; 4-ml Gd) and five-phase, HR-based imaging protocol (0, 30, 70, 120, and 240s; 0.05mmol/kg Gd) were prospectively performed in twelve volunteers who were scheduled for routine renal MRI. Data were plotted with Patlak, two-compartment modified Tofts model (2CTM), and two-compartment filtration model (2CFM) for GFR estimate. During all the measurements, only the signal intensities in the aorta and whole kidney parenchyma were considered. Standard 2CFM and 2CTM produced lower residuals over the fitted interval than HR-based measures (p<0.05); and HR-bases 2CFM and 2CTM did not reflect significant correlation to standard values. Standard Patlak plots with 0-240s data points produced significantly lower GFR and higher residuals than that plots with 0-120s data points (p<0.05). HR-based Patlak plots with 0, 30, 70, and 120s data points significantly correlated with reference values (Pearson ρ=0.97, p<0.01), and produced a 33.2% underestimation of reference value, which was better than that plots with 0, 30, 70, 120, and 240s data points (ρ=0.92, p<0.01; 58.6% underestimation of reference value). It concludes that it is feasible to estimate GFR with HR-based DCE-MRI and appreciate kinetic model. Patlak plots from 0, 30, 70, and 120s data points is better than plots from 0, 30, 70, 120, and 240s data points.<br /> (Copyright © 2015 Elsevier Inc. All rights reserved.)
- Subjects :
- Adult
Computer Simulation
Contrast Media pharmacokinetics
Feasibility Studies
Female
Humans
Kidney anatomy & histology
Male
Middle Aged
Reproducibility of Results
Sensitivity and Specificity
Young Adult
Gadolinium DTPA pharmacokinetics
Glomerular Filtration Rate physiology
Image Interpretation, Computer-Assisted methods
Kidney physiology
Magnetic Resonance Imaging methods
Models, Biological
Subjects
Details
- Language :
- English
- ISSN :
- 1873-5894
- Volume :
- 33
- Issue :
- 8
- Database :
- MEDLINE
- Journal :
- Magnetic resonance imaging
- Publication Type :
- Academic Journal
- Accession number :
- 26004284
- Full Text :
- https://doi.org/10.1016/j.mri.2015.05.005