Back to Search Start Over

Comparison of endothelium-dependent and -independent vasomotor response after abluminal biodegradable polymer biolimus-eluting stent and persistent polymer everolimus-eluting stent implantation (COMPARE-IT).

Authors :
Puricel S
Kallinikou Z
Espinola J
Arroyo D
Goy JJ
Stauffer JC
Baeriswyl G
Smits PC
Cook S
Togni M
Source :
International journal of cardiology [Int J Cardiol] 2016 Jan 01; Vol. 202, pp. 525-31. Date of Electronic Publication: 2015 Sep 26.
Publication Year :
2016

Abstract

Background: Drug-eluting stents (DES) have been associated with local endothelial dysfunction in the segments proximal and distal to the stent (peristent segments) and increased thrombotic risk in long term follow-up. Little data exists on endothelial function post-implantation of new DES with biodegradable polymer. The aim of our study was to compare the local endothelial function assessed by exercise induced coronary vasomotion after implantation of a biolimus A9-eluting stent with biodegradable polymer (BES) with an everolimus-eluting stent with durable polymer (EES).<br />Methods: Coronary vasomotion was evaluated with quantitative coronary angiography at rest and during supine bicycle exercise in nine patients with EES and thirteen patients with BES, 16 months after stent implantation. Mean luminal diameter of the stent, peristent segments, and of a control vessel were determined at rest, during exercise, and after the administration of nitroglycerine.<br />Results: The control vessel showed exercise-induced vasodilatation in both groups (EES: +6.4±5.5%, p=0.07; BES: +7.8±10.1%, p=0.07). Vasomotion in the stented vessel segment was abolished. There was exercise-induced vasoconstriction in both groups in the segments proximal (EES: -9.6±4.5%; p=0.03; BES: -4.3±5.4%, p=0.02) and distal to the stent (EES: -3.2±9.3%; p=0.41, BES -8.6±8.0%, p<0.01). Sublingual nitroglycerin was associated with maximal vasodilatation of the peristent segments in both groups.<br />Conclusion: Alike DES with durable polymer, stents with a biodegradable polymer are associated with exercise-induced paradoxical coronary vasoconstriction of the peristent segments. This data suggests that endothelial dysfunction after DES implantation is not primarily caused by the durability of the polymer coating.<br /> (Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.)

Details

Language :
English
ISSN :
1874-1754
Volume :
202
Database :
MEDLINE
Journal :
International journal of cardiology
Publication Type :
Academic Journal
Accession number :
26440470
Full Text :
https://doi.org/10.1016/j.ijcard.2015.09.085