Comparative analysis of iterative reconstruction algorithms with resolution recovery and time of flight modeling for 18 F-FDG cardiac PET: A multi-center phantom study.
- Source :
-
Journal of nuclear cardiology : official publication of the American Society of Nuclear Cardiology [J Nucl Cardiol] 2017 Jun; Vol. 24 (3), pp. 1036-1045. Date of Electronic Publication: 2016 Jan 12. - Publication Year :
- 2017
-
Abstract
- Background: The purpose of this study was to evaluate the image quality in cardiac <superscript>18</superscript> F-FDG PET using the time of flight (TOF) and/or point spread function (PSF) modeling in the iterative reconstruction (IR).<br />Methods: Three scanners and an anthropomorphic cardiac phantom with an insert simulating a transmural defect (TD) were used. Two sets of scans (with/without TD) were acquired, and four reconstruction schemes were considered: (1) IR; (2) IR + PSF, (3) IR + TOF, and (4) IR + TOF + PSF. LV wall thickness (FWHM), contrast between LV wall and inner chamber (C <subscript>IC</subscript> ), and TD contrast in LV wall (C <subscript>TD</subscript> ) were evaluated.<br />Results: Tests of the reconstruction protocols showed a decrease in FWHM from IR (13 mm) to IR + PSF (11 mm); an increase in the C <subscript>IC</subscript> from IR (65%) to IR + PSF (71%) and from IR + TOF (72%) to IR + TOF + PSF (77%); and an increase in the C <subscript>TD</subscript> from IR + PSF (72%) to IR + TOF (75%) and to IR + TOF + PSF (77%). Tests of the scanner/software combinations showed a decrease in FWHM from Gemini&#95;TF (13 mm) to Biograph&#95;mCT (12 mm) and to Discovery&#95;690 (11 mm); an increase in the C <subscript>IC</subscript> from Gemini&#95;TF (65%) to Biograph&#95;mCT (73%) and to Discovery&#95;690 (75%); and an increase in the C <subscript>TD</subscript> from Gemini&#95;TF/Biograph&#95;mCT (72%) to Discovery&#95;690 (77%).<br />Conclusion: The introduction of TOF and PSF increases image quality in cardiac <superscript>18</superscript> F-FDG PET. The scanner/software combinations exhibit different performances, which should be taken into consideration when making cross comparisons.
- Subjects :
- Cardiac Imaging Techniques instrumentation
Image Enhancement methods
Italy
Phantoms, Imaging
Positron-Emission Tomography instrumentation
Radiopharmaceuticals
Reproducibility of Results
Sensitivity and Specificity
Software
Algorithms
Cardiac Imaging Techniques methods
Fluorodeoxyglucose F18
Heart Ventricles diagnostic imaging
Image Interpretation, Computer-Assisted methods
Positron-Emission Tomography methods
Subjects
Details
- Language :
- English
- ISSN :
- 1532-6551
- Volume :
- 24
- Issue :
- 3
- Database :
- MEDLINE
- Journal :
- Journal of nuclear cardiology : official publication of the American Society of Nuclear Cardiology
- Publication Type :
- Academic Journal
- Accession number :
- 26758376
- Full Text :
- https://doi.org/10.1007/s12350-015-0385-z