Back to Search
Start Over
Clinical validation of Anyplex™ II HPV HR Detection according to the guidelines for HPV test requirements for cervical cancer screening.
- Source :
-
Journal of clinical virology : the official publication of the Pan American Society for Clinical Virology [J Clin Virol] 2016 Mar; Vol. 76, pp. 36-9. Date of Electronic Publication: 2016 Jan 15. - Publication Year :
- 2016
-
Abstract
- Background: Anyplex™ II HPV HR Detection (Seegene, Seoul, Korea) is a multiplex real-time PCR using tagging oligonucleotide cleavage and extension (TOCE) technology for simultaneous detection and genotyping of 14 high-risk (HR) HPV types, including HPV16 and HPV18.<br />Objectives: To evaluate whether the clinical performance and reproducibility of Anyplex™ II HPV HR Detection meet the international consensus guidelines for HPV test requirements for cervical cancer screening [1].<br />Study Design: The clinical performance of Anyplex™ II HPV HR Detection for detecting cervical intraepithelial neoplasia grade 2 or worse (CIN2+) was determined relative to that of the reference assay, i.e., HR HPV GP5+/6+-PCR-EIA, by analysis of a total of 879 cervical liquid based cytology (LBC) specimens from a screening population, of which 60 were from women with CIN2+. The intra-laboratory reproducibility and inter-laboratory agreement were determined on 509 LBC samples, of which 172 were positive by the reference assay.<br />Results: Anyplex™ II HPV HR Detection showed a clinical sensitivity for CIN2+ of 98.3% (59/60; 95% CI: 89.1-99.8) and a clinical specificity for CIN2+ of 93.6% (764/816; 95% CI: 89.8-96.1). The clinical sensitivity and specificity were non-inferior to those of HR HPV GP5+/6+-PCR-EIA (non-inferiority score test: P=0.005 and P=0.023, respectively). Both intra-laboratory reproducibility (96.8%; 95% CI: 95.3-98.1; kappa value of 0.93) and inter-laboratory agreement (96.0%; 95% CI: 94.3-97.4; kappa value of 0.91) were high.<br />Conclusions: Anyplex™ II HPV HR Detection performs clinically non-inferior to HR HPV GP5+/6+-PCR-EIA. Anyplex™ II HPV HR Detection complies with international consensus validation metrics for HPV DNA tests for cervical cancer screening [1].<br /> (Copyright © 2016 Elsevier B.V. All rights reserved.)
- Subjects :
- Adult
Alphapapillomavirus genetics
Colposcopy
Early Detection of Cancer methods
Female
Genotype
Humans
Mass Screening
Middle Aged
Papillomavirus Infections prevention & control
Papillomavirus Infections virology
Pregnancy
Reagent Kits, Diagnostic
Real-Time Polymerase Chain Reaction
Reproducibility of Results
Republic of Korea
Sensitivity and Specificity
Uterine Cervical Neoplasms virology
Uterine Cervical Dysplasia virology
Alphapapillomavirus isolation & purification
Papillomavirus Infections diagnosis
Uterine Cervical Neoplasms diagnosis
Uterine Cervical Neoplasms prevention & control
Uterine Cervical Dysplasia diagnosis
Uterine Cervical Dysplasia prevention & control
Subjects
Details
- Language :
- English
- ISSN :
- 1873-5967
- Volume :
- 76
- Database :
- MEDLINE
- Journal :
- Journal of clinical virology : the official publication of the Pan American Society for Clinical Virology
- Publication Type :
- Academic Journal
- Accession number :
- 26809131
- Full Text :
- https://doi.org/10.1016/j.jcv.2016.01.009