Comparison of phase dyssynchrony analysis using gated myocardial perfusion imaging with four software programs: Based on the Japanese Society of Nuclear Medicine working group normal database.
- Source :
-
Journal of nuclear cardiology : official publication of the American Society of Nuclear Cardiology [J Nucl Cardiol] 2017 Apr; Vol. 24 (2), pp. 611-621. Date of Electronic Publication: 2016 Feb 09. - Publication Year :
- 2017
-
Abstract
- Purpose: Left ventricular (LV) phase dyssynchrony parameters based on gated myocardial perfusion imaging varied among software programs. The aim of this study was to determine normal ranges and factors affecting phase parameters.<br />Methods: Normal databases were derived from the Japanese Society of Nuclear Medicine working group (n = 69). The programs were Emory Cardiac Toolbox with SyncTool (ECTb), Quantitative Gated SPECT (QGS), Heart Function View (HFV), and cardioREPO (cREPO); parameters of phase standard deviation (PSD), 95% bandwidth, and entropy were compared with parameters with ECTb as a reference.<br />Results: PSD (degree) was 5.3 ± 3.3 for QGS (P < .0001), 5.4 ± 2.5 for HFV (P < .0001), and 10.3 ± 3.2 for cREPO (P = n. s.) compared with 11.5 ± 5.5 for ECTb. Phase bandwidth with three programs differed significantly from ECTb. Gender differences were significant for all programs, indicating larger variation in males. After adjustment of LV volumes between genders, the difference disappeared except for QGS. The phase parameters showed wider variations in patients with the lower ejection fraction (EF) and larger LV volumes, depending on software types.<br />Conclusion: Based on normal ranges of phase dyssynchrony parameters in four software programs, dependency on genders, LV volume, and EF should be considered, indicating the need for careful comparison among different software programs.
- Subjects :
- Aged
Databases, Factual
Female
Humans
Image Enhancement methods
Japan
Male
Middle Aged
Reproducibility of Results
Sensitivity and Specificity
Algorithms
Cardiac-Gated Single-Photon Emission Computer-Assisted Tomography methods
Gated Blood-Pool Imaging methods
Image Interpretation, Computer-Assisted methods
Software
Ventricular Dysfunction, Left diagnostic imaging
Subjects
Details
- Language :
- English
- ISSN :
- 1532-6551
- Volume :
- 24
- Issue :
- 2
- Database :
- MEDLINE
- Journal :
- Journal of nuclear cardiology : official publication of the American Society of Nuclear Cardiology
- Publication Type :
- Academic Journal
- Accession number :
- 26860109
- Full Text :
- https://doi.org/10.1007/s12350-015-0333-y