Back to Search Start Over

Ceramic brackets and low friction : A possible synergy in patients requiring multiple MRI scanning.

Authors :
Camporesi M
Bulhoes Galvão M
Tortamano A
Dominguez GC
Defraia N
Defraia E
Franchi L
Source :
Journal of orofacial orthopedics = Fortschritte der Kieferorthopadie : Organ/official journal Deutsche Gesellschaft fur Kieferorthopadie [J Orofac Orthop] 2016 May; Vol. 77 (3), pp. 214-23. Date of Electronic Publication: 2016 Apr 20.
Publication Year :
2016

Abstract

Aim: To investigate any advantages of low friction biomechanics in orthodontic patients with fixed appliances without producing metal artifacts during magnetic resonance imaging (MRI).<br />Materials and Methods: Frictional resistance generated by bracket-wire-ligature systems was analyzed via an experimental model that reproduced upper canine misalignment. Each sample was tested 10 consecutive times in a dry state; a total of 160 tests were carried out. We documented the frictional forces generated by a 0.012- and 0.014-inch superelastic nickel-titanium wire (SENT) with ceramic self-ligating brackets (SLB) with metal insert and ceramic monocrystalline brackets with nonconventional elastic ligatures (NCEL) in conjunction with various degrees of canine misalignment (1.5, 3.0, 4.5, and 6.0 mm). Comparisons between the frictional forces released by the two different bracket-wire-ligature systems were made by conducting 3-way analysis of variance (ANOVA) with Tukey HSD pairwise test (P < 0.005).<br />Results: We observed no clinically relevant difference between the frictional forces released by ceramic SLB and ceramic brackets in conjunction with a 0.012- and 0.014-inch SENT. Statistically significant differences were apparent with a 0.012-inch SENT at 4.5 and 6.0 mm of canine misalignment, where the SLB revealed higher frictional forces.<br />Conclusions: Ceramic brackets with NCEL revealed frictional forces similar to those generated in conjunction with ceramic SLB, thereby helping to avoid metal artifacts in case of expected necessary MRI during orthodontic treatment with fixed appliances.

Details

Language :
English
ISSN :
1615-6714
Volume :
77
Issue :
3
Database :
MEDLINE
Journal :
Journal of orofacial orthopedics = Fortschritte der Kieferorthopadie : Organ/official journal Deutsche Gesellschaft fur Kieferorthopadie
Publication Type :
Academic Journal
Accession number :
27098639
Full Text :
https://doi.org/10.1007/s00056-016-0027-3