Back to Search
Start Over
Comparison of Iohexol-380 and Iohexol-350 for Coronary CT Angiography: A Multicenter, Randomized, Double-Blind Phase 3 Trial.
- Source :
-
Korean journal of radiology [Korean J Radiol] 2016 May-Jun; Vol. 17 (3), pp. 330-8. Date of Electronic Publication: 2016 Apr 14. - Publication Year :
- 2016
-
Abstract
- Objective: This multi-center, randomized, double-blind, phase 3 trial was conducted to compare the safety and efficacy of contrast agents iohexol-380 and iohexol-350 for coronary CT angiography in healthy subjects.<br />Materials and Methods: Volunteers were randomized to receive 420 mgI/kg of either iohexol-350 or iohexol-380 using a flow rate of 4 mL/sec. All adverse events were recorded. Two blinded readers independently reviewed the CT images and conflicting results were resolved by a third reader. Luminal attenuations (ascending aorta, left main coronary artery, and left ventricle) in Hounsfield units (HUs) and image quality on a 4-point scale were calculated.<br />Results: A total of 225 subjects were given contrast media (115 with iohexol-380 and 110 with iohexol-350). There was no difference in number of adverse drug reactions between groups: 75 events in 56 (48.7%) of 115 subjects in the iohexol-380 group vs. 74 events in 51 (46.4%) of 110 subjects in the iohexol-350 group (p = 0.690). No severe adverse drug reactions were recorded. Neither group showed an increase in serum creatinine. Significant differences in mean density between the groups was found in the ascending aorta: 375.8 ± 71.4 HU with iohexol-380 vs. 356.3 ± 61.5 HU with iohexol-350 (p = 0.030). No significant differences in image quality scores between both groups were observed for all three anatomic evaluations (all, p > 0.05).<br />Conclusion: Iohexol-380 provides improved enhancement of the ascending aorta and similar attenuation of the coronary arteries without any increase in adverse drug reactions, as compared with iohexol-350 using an identical amount of total iodine.
- Subjects :
- Adult
Aged
Aorta diagnostic imaging
Contrast Media adverse effects
Creatinine blood
Double-Blind Method
Electrocardiography
Female
Gastrointestinal Diseases etiology
Healthy Volunteers
Humans
Image Interpretation, Computer-Assisted
Iohexol adverse effects
Male
Middle Aged
Nervous System Diseases etiology
Skin Diseases etiology
Young Adult
Computed Tomography Angiography methods
Contrast Media chemistry
Coronary Vessels diagnostic imaging
Iohexol chemistry
Subjects
Details
- Language :
- English
- ISSN :
- 2005-8330
- Volume :
- 17
- Issue :
- 3
- Database :
- MEDLINE
- Journal :
- Korean journal of radiology
- Publication Type :
- Academic Journal
- Accession number :
- 27134522
- Full Text :
- https://doi.org/10.3348/kjr.2016.17.3.330